Browse all help

Guides

How do I…?

Signing in and the app7
Doing jobs13
Checking jobs and running the team10
Setting up and managing17
Collection, intake and gate7

By type of organisation

IT Park / SEZ / Business Park: setup and training guide

On this page

This page is the part of the onboarding kit that is specific to a IT Park / SEZ / Business Park. It lists what the app will set up for you, who in your team normally does each piece, and what you need to have ready. How to use the app is in the shared guides, which are the same for every organisation:

The lists below come from the same rule set the app uses, so they match what you will see. What actually applies to your site depends on your answers during setup: a rule marked "depends on your site" is only switched on if you have, for example, a borewell or a kitchen.

1. At a glance

WhatHow many (maximum)
Rules that apply to every IT Park8
Rules that depend on what is on your site17
Good-practice rules (recommended)6
One-time setup items (photos, documents, certificates)71
Recurring jobs (daily to yearly)73
Things you log when they happen21
Licence renewals tracked19
Statutory filings8

Most sites end up with fewer than the maximum, because the setup questions switch off what does not apply.

2. Who you need on the app

Each row is a job in your organisation, not necessarily a separate person. In a small site one person often holds several rows: the manager is usually also the compliance officer. Every person signs in with their own account, so the record shows who did what.

RoleApp accessWhat they look afterNeeded?Items they own
ManagerManagerOverall park compliance, SWM return, BRSRYes59
Compliance officerManagerSEBI BRSR, tenant data aggregationYes42
Chiller / HVAC engineerSupervisorChiller plant, refrigerant and leak records.Only if your site needs it2
DG / power engineerSupervisorDG run log, stack emission, SPCB reporting: gated on dgCountOnly if your site needs it6
Tenant compliance liaisonSupervisorTenant agreements, tenant FSSAI/e-waste audits: multi-tenant parksOnly if your site needs it3
Operations supervisorSupervisorDay-to-day park operationsYes53
Housekeeping / floor staffWorkerDaily waste log, SWM tasksYes23
Kitchen supervisorSupervisorManages FSSAI compliance for canteen/kitchen operationsOnly if your site needs it4

App access decides what a person sees. Manager: the web portal and the phone app, with setup, approvals, reports and filings. Supervisor: the phone app, with their team's jobs and approvals. Worker: the phone app, with their own jobs only.

3. Before setup: have these ready

Questions the setup will ask about your site

Setup takes about 30 to 45 minutes if you have these answers to hand. "Not sure" is fine for anything you can find out later; you can change answers afterwards.

Numbers

  • Total DG Capacity Kva
  • DG Count
  • Fuel Storage Litres
  • Active Tenant Company Count
  • Number of lifts
  • Number of escalators / moving walks
  • Connected electrical load (kW)
  • Age of the building (years)
  • Contract workers engaged through contractors
  • Plot area (sq m)
  • Solar plant capacity (kW)
  • LPG stored on site (kg, all cylinders together)
  • Number of employees / workers on site

Yes or no

  • Active renovation on site?
  • Borewell on site?
  • Central chiller on site?
  • Hsd storage or solvent tenant on site?
  • Is SEBI Listed Or Tenant Reporting?
  • Requires Cems?
  • Is Ewaste Large Generator?
  • Is Ewaste Producer?
  • Food court on site?
  • Uses more than 50 litres of frying oil a day (FSSAI UCO threshold)?
  • Hands over e-waste to authorised recycler / take-back programme?
  • Sells/routes dry recyclables to authorised vendor / recycler?
  • hasCanteen?
  • hasCorporateEvents?
  • Rainwater harvesting on site?
  • Multi tenant oversight on site?
  • STP on site?
  • Is Bwg?
  • Employs 10 or more people (incl. contract/interns)?
  • Uses septic tank / storage tank (no onsite STP)?
  • Local body requires a trade licence?
  • Security guards supplied by an agency?
  • Holds an SPCB consent (Water / Air Act) or hazardous-waste authorisation?
  • Holds an Environmental Clearance (EIA 2006)?
  • State law requires rainwater harvesting here (derived from state and plot area; not asked)?
  • Swimming pool on the premises?
  • Rooftop / ground-mounted solar plant on site?
  • EV charging points in the parking?
  • Commercial piped natural gas (PNG) connection?
  • Drinking water comes from a borewell or tanker (not only the municipal supply)?
  • Cooling tower / central chiller plant on site?

Other details

  • No-STP wastewater scenario

Documents and licences to gather

Collect what you already have as PDFs or clear phone photos. Anything you do not have yet stays on your list as a gap; it does not block setup.

DocumentNeeded
☐ Continuous Emission Monitoring System (CEMS) installation certificate (for large DG clusters where CPCB/SPCB requires CEMS)If Air Act 1981 applies
☐ Tenant e-waste compliance agreement (park-level requirement that each tenant hands EOL IT to registered recycler)Always
☐ Tenant SUP ban agreement (all food/retail tenants must comply with PWM SUP ban)Always
☐ Electrical and electronic equipment (EEE) asset registerAlways
☐ IT asset disposal policy and vendor empanelment documentAlways
☐ CPCB-registered e-waste recycler authorization copyAlways
☐ Battery asset register (UPS/inverter/solar systems)Always
☐ CPCB-authorized battery recycler authorization copyAlways
☐ CPCB BWG registrationAlways
☐ CPCB PIBO EPR registration (own-brand products)Always
☐ FSSAI licenseAlways
☐ STP Consent to Operate from SPCB (each STP)Always
☐ CGWA NOC or exemption certificateIf CGWA Groundwater Rules applies
☐ Rainwater harvesting system installation certificate (each rainwater pit)If CGWA Groundwater Rules / Rainwater harvesting applies
☐ PESO petroleum storage licenseIf Petroleum Act + PESO applies
☐ Fire Safety NOC from State Fire ServiceAlways
☐ C&D Waste Management PlanIf C&D Waste Management Rules 2025 applies
☐ ULB approval/intimation for large C&D projectsIf C&D Waste Management Rules 2025 applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)Always
☐ Compliant carry-bag procurement recordAlways
☐ SPCB HWM authorizationIf HWM Rules 2016 applies
☐ DG exhaust stack height compliance certificate (each DG set)If Air Act 1981 applies
☐ SPCB Consent to Operate for DG (state-conditional)If Air Act 1981 applies
☐ PIBO role assessment (own-brand packaging — drives CPCB PWM EPR registration obligation)Always
☐ Shops & Establishments Act registrationAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)If POSH Internal Complaints Committee applies
☐ HVAC refrigerant inventory registerAlways
☐ HVAC technician training/certification copyAlways
☐ R-22 phase-out plan documentAlways
☐ Lift licence / registration (each lift)If Lifts & escalators applies
☐ Lift maintenance contract (AMC)If Lifts & escalators applies
☐ Lift third-party insuranceIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationAlways
☐ Electrical Safety Officer appointmentAlways
☐ Fire-safe wiring and supply isolation certificateAlways
☐ Municipal trade / health trade licenceIf Trade licence applies
☐ Occupancy / completion certificateAlways
☐ Structural stability certificateAlways
☐ Contractor labour licences (50 or more contract workers)Always
☐ Security agency licence (PSARA)Always
☐ Privacy notice for residents / visitors / customers / staffAlways
☐ Personal data breach response planAlways
☐ EIA Environment Clearance conditions documentIf Environmental Clearance (EIA) applies
☐ Permission to operate the swimming pool (Tamil Nadu, Form VI)If Swimming pool applies
☐ Electrical Inspector approval of the rooftop solar plantAlways
☐ Self-certification of the rooftop solar plantAlways
☐ Net-metering / grid connection agreement with the discomAlways
☐ EVSE electrical commissioning certificate (BIS/CEA/DISCOM)If EV Charging Safety applies
☐ PESO storage licence for the LPG cylinder bank (above 100 kg)Always
☐ Piped natural gas (PNG) installation third-party safety certificateAlways
☐ Crèche facility for employees' children (50 or more employees)Always
☐ Pest-control operator's licence (Insecticides Rules 1971)Always

4. Setup evidence: your first-weeks checklist

Setup evidence is the one-time proof of what is on your site: a photo of each bin, the STP nameplate, a copy of each licence. After setup each item appears as a job under Setup Evidence. Photo items for equipment start with a scan of that item's QR sticker, so stick the stickers on first (see Setup evidence and QR stickers).

Chiller / HVAC engineer

ItemEvidenceNeeded
☐ Continuous Emission Monitoring System (CEMS) installation certificate (for large DG clusters where CPCB/SPCB requires CEMS)CertificateIf Air Act 1981 applies

Tenant compliance liaison

ItemEvidenceNeeded
☐ Tenant e-waste compliance agreement (park-level requirement that each tenant hands EOL IT to registered recycler)DocumentAlways
☐ Tenant SUP ban agreement (all food/retail tenants must comply with PWM SUP ban)DocumentAlways

Manager

ItemEvidenceNeeded
☐ Electrical and electronic equipment (EEE) asset registerDocumentAlways
☐ Battery asset register (UPS/inverter/solar systems)DocumentAlways
☐ Bin overview photo (position, label & lid) — per bin (each bin)PhotoAlways
☐ Rainwater harvesting system installation certificate (each rainwater pit)DocumentIf CGWA Groundwater Rules / Rainwater harvesting applies
☐ Secondary containment (bunding) photoPhotoIf Petroleum Act + PESO applies
☐ C&D Waste Management PlanDocumentIf C&D Waste Management Rules 2025 applies
☐ Multilingual segregation signagePhotoAlways
☐ Compliant carry-bag procurement recordDocumentAlways
☐ STP full installation overview (each STP)PhotoAlways
☐ Consent-to-Operate document displayed near STP (each STP)PhotoAlways
☐ Composting unit full overview (each compost unit)PhotoAlways
☐ Diesel generator (DG) set — full installation overview (each DG set)PhotoIf Air Act 1981 applies
☐ HVAC refrigerant inventory registerDocumentAlways
☐ HVAC technician training/certification copyDocumentAlways
☐ Lift / escalator nameplate photo (each lift)PhotoIf Lifts & escalators applies
☐ Lift licence / registration (each lift)CertificateIf Lifts & escalators applies
☐ Lift maintenance contract (AMC)CertificateIf Lifts & escalators applies
☐ Lift third-party insuranceCertificateIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationCertificateAlways
☐ Electrical Safety Officer appointmentDocumentAlways
☐ Fire-safe wiring and supply isolation certificateDocumentAlways
☐ Municipal trade / health trade licenceCertificateIf Trade licence applies
☐ Occupancy / completion certificateCertificateAlways
☐ Structural stability certificateCertificateAlways
☐ Contractor labour licences (50 or more contract workers)CertificateAlways
☐ Security agency licence (PSARA)CertificateAlways
☐ Privacy notice for residents / visitors / customers / staffDocumentAlways
☐ Named contact for personal-data grievancesDeclarationAlways
☐ Personal data breach response planDocumentAlways
☐ EIA Environment Clearance conditions documentDocumentIf Environmental Clearance (EIA) applies
☐ Permission to operate the swimming pool (Tamil Nadu, Form VI)CertificateIf Swimming pool applies
☐ Electrical Inspector approval of the rooftop solar plantDocumentAlways
☐ Self-certification of the rooftop solar plantDocumentAlways
☐ Net-metering / grid connection agreement with the discomDocumentAlways
☐ EVSE electrical commissioning certificate (BIS/CEA/DISCOM)CertificateIf EV Charging Safety applies
☐ PESO storage licence for the LPG cylinder bank (above 100 kg)CertificateAlways
☐ Piped natural gas (PNG) installation third-party safety certificateCertificateAlways
☐ Crèche facility for employees' children (50 or more employees)DocumentAlways
☐ Pest-control operator's licence (Insecticides Rules 1971)CertificateAlways

Compliance officer

ItemEvidenceNeeded
☐ IT asset disposal policy and vendor empanelment documentDocumentAlways
☐ CPCB-registered e-waste recycler authorization copyCertificateAlways
☐ CPCB-authorized battery recycler authorization copyCertificateAlways
☐ CPCB BWG registrationCertificateAlways
☐ CPCB PIBO EPR registration (own-brand products)CertificateAlways
☐ FSSAI licenseCertificateAlways
☐ STP Consent to Operate from SPCB (each STP)CertificateAlways
☐ CGWA NOC or exemption certificateCertificateIf CGWA Groundwater Rules applies
☐ PESO petroleum storage licenseCertificateIf Petroleum Act + PESO applies
☐ Fire Safety NOC from State Fire ServiceCertificateAlways
☐ ULB approval/intimation for large C&D projectsDocumentIf C&D Waste Management Rules 2025 applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)CertificateAlways
☐ SPCB HWM authorizationCertificateIf HWM Rules 2016 applies
☐ SPCB Consent to Operate for DG (state-conditional)CertificateIf Air Act 1981 applies
☐ PIBO role assessment (own-brand packaging — drives CPCB PWM EPR registration obligation)DocumentAlways
☐ Shops & Establishments Act registrationCertificateAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)DocumentIf POSH Internal Complaints Committee applies
☐ R-22 phase-out plan documentDocumentAlways

DG / power engineer

ItemEvidenceNeeded
☐ DG acoustic enclosure installation photo (each DG set)PhotoAlways
☐ DG exhaust stack height compliance certificate (each DG set)DocumentIf Air Act 1981 applies

Operations supervisor

ItemEvidenceNeeded
☐ Four-stream segregation signage and bin infrastructure photoPhotoAlways
☐ STP capacity nameplate or equipment label (each STP)PhotoAlways
☐ STP inlet connection from building drainage (each STP)PhotoAlways
☐ STP outlet pipe destination connection (each STP)PhotoAlways
☐ STP sludge disposal / drying area (each STP)PhotoAlways
☐ Composting unit capacity label (each compost unit)PhotoAlways
☐ Compost output storage area (each compost unit)PhotoAlways
☐ Diesel generator (DG) capacity nameplate (each DG set)PhotoIf Air Act 1981 applies
☐ Electrical danger notices and shock-treatment chartPhotoAlways

5. Your recurring jobs

These are created automatically once setup is done and come back on their own schedule. Each shows on the phone of the person it is assigned to. The "Usually done by" column is the default; the manager can reassign any job (see Manager guide).

Every day

JobUsually done byEvidenceNeeded
Daily waste weighment logHousekeeping / floor staffReadingsAlways
Food and garden waste composting / processing logHousekeeping / floor staffReadingsAlways
Daily garden/leaf waste composting or disposal logHousekeeping / floor staffReadingsAlways
PM POSHAN / MDM daily quality inspection and tasting recordKitchen supervisorChecklistAlways
Daily C&D waste volume log by categoryHousekeeping / floor staffReadingsIf C&D Waste Management Rules 2025 applies
Daily borewell pump run log (each borewell)Housekeeping / floor staffReadingsIf CGWA Groundwater Rules applies
Daily pool water pH and free chlorine logOperations supervisorReadingsIf Swimming pool applies

Every week

JobUsually done byEvidenceNeeded
On-site C&D waste segregation zone photo (4-category)Housekeeping / floor staffPhotoIf C&D Waste Management Rules 2025 applies
No unauthorized C&D dumping declarationOperations supervisorDeclarationIf C&D Waste Management Rules 2025 applies
Weekly segregation spot check (each floor)Operations supervisorPhotoAlways
Weekly dry recyclable sale / handover to authorized buyerCompliance officerReadingsIf Dry Recyclable Sale to Authorized Buyer applies
Weekly groundwater abstraction log (per borewell) (each borewell)Housekeeping / floor staffReadingsIf CGWA Groundwater Rules applies

Every month

JobUsually done byEvidenceNeeded
Monthly check — no e-waste in general waste binsHousekeeping / floor staffChecklistAlways
Monthly check — no batteries in general wasteHousekeeping / floor staffChecklistAlways
Dry waste dispatch to authorized recyclerHousekeeping / floor staffDocumentAlways
Monthly no-open-burning declarationOperations supervisorDeclarationAlways
STP sludge disposal log (each STP)Housekeeping / floor staffDocumentAlways
Monthly single-use plastic ban auditOperations supervisorChecklistAlways
Dry plastic waste to authorized recyclerOperations supervisorDocumentAlways
UCO handover to FSSAI-registered aggregatorHousekeeping / floor staffDocumentAlways
Monthly Schedule 4 hygiene inspectionKitchen supervisorChecklistAlways
Pest control treatment recordKitchen supervisorDocumentAlways
Monthly STP performance log (each STP)Housekeeping / floor staffReadingsAlways
Monthly STP effluent quality test (each STP)Operations supervisorDocumentAlways
Treated effluent reuse log (gardening/flushing) (each STP)Housekeeping / floor staffReadingsAlways
No effluent to groundwater declarationOperations supervisorDeclarationAlways
Monthly groundwater level monitoring (each borewell)Housekeeping / floor staffReadingsIf CGWA Groundwater Rules applies
Fire system maintenance (extinguishers, hydrants, sprinklers)Operations supervisorDocumentAlways
Pool chemical waste disposal logCompliance officerDocumentIf HWM Rules 2016 / Swimming pool applies
HWM storage inspection (≤90 days, no mixing)Operations supervisorPhotoIf HWM Rules 2016 applies
Plastic waste segregation log (dry stream + MLP tracking)Housekeeping / floor staffReadingsAlways
Sanitary waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Special-care waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Monthly rainwater harvesting structure maintenance log (each rainwater pit)Operations supervisorDocumentIf CGWA Groundwater Rules / Rainwater harvesting applies
Septic tank / cesspool desludging log (each septic tank)Housekeeping / floor staffDocumentAlways
Monthly lift maintenance visit (each lift)Operations supervisorChecklistIf Lifts & escalators applies
Monthly first-aid box checkOperations supervisorChecklistAlways
Used engine oil handover to a registered collection agent / recyclerOperations supervisorReadingsIf HWM Rules 2016 applies
Monthly pool lifeguard and safety equipment checkOperations supervisorChecklistIf Swimming pool applies
Cooling tower blowdown water quality and disposal logOperations supervisorDocumentAlways

Every quarter

JobUsually done byEvidenceNeeded
Quarterly data centre / UPS room / DG room fire safety checkOperations supervisorChecklistAlways
Quarterly fire escape signage and emergency lighting checkOperations supervisorPhotoAlways
Fire drill and staff evacuation training recordOperations supervisorDocumentAlways
Periodic e-waste handover log to authorised recyclerHousekeeping / floor staffDocumentIf Periodic E-Waste Handover Log to Authorised Recycler applies
Quarterly lift test by a registered person (each lift)Operations supervisorDocumentIf Lifts & escalators applies
Lift rescue device, alarm and intercom check (each lift)Operations supervisorChecklistIf Lifts & escalators applies
Quarterly EV charging bay electrical safety inspectionOperations supervisorChecklistIf EV Charging Safety applies
Quarterly LPG/CNG gas installation safety checkOperations supervisorDocumentAlways

Every six months

JobUsually done byEvidenceNeeded
Half-yearly drinking water quality test (IS 10500)Compliance officerDocumentAlways
6-monthly certified fire system inspection (IS 2190)Compliance officerDocumentAlways
Six-monthly lift test by an authorised person (each lift)Operations supervisorDocumentIf Lifts & escalators applies
Lift rescue mock drillOperations supervisorDocumentIf Lifts & escalators applies
6-monthly EC compliance report (if EC granted)ManagerDocumentIf Environmental Clearance (EIA) applies

Every year

JobUsually done byEvidenceNeeded
Annual audit that all food court / cafeteria tenants hold valid FSSAI licenseTenant compliance liaisonDocumentAlways
Annual tenant-level ESG data collection for BRSR reportingCompliance officerDocumentIf BRSR / SEBI applies
Annual BRSR environmental data compilationCompliance officerDocumentIf BRSR / SEBI applies
Annual Scope 1/2/3 GHG calculation reportCompliance officerDocumentIf BRSR / SEBI applies
Kitchen staff annual health certificateManagerDocumentAlways
Annual pre-monsoon groundwater quality test (each borewell)Operations supervisorDocumentIf CGWA Groundwater Rules applies
Annual noise level test at property boundaryOperations supervisorDocumentAlways
Annual HSD tank integrity inspectionManagerDocumentIf Petroleum Act + PESO applies
Fuel storage area fire safety checkOperations supervisorChecklistIf Petroleum Act + PESO applies
Annual refrigerant top-up review and leak auditCompliance officerDocumentAlways
Green/recycled-content procurement recordManagerDeclarationAlways
Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set)DG / power engineerDocumentIf Air Act 1981 applies
Annual fire system service / hydro-test (IS 2190)Compliance officerDocumentAlways
POSH annual report to District OfficerCompliance officerDocumentIf POSH Internal Complaints Committee applies
2-year STP installation plan / approval (no on-site STP)Compliance officerDocumentAlways
Annual lift safety certificate / inspection reportOperations supervisorDocumentIf Lifts & escalators applies
Annual earth resistance testOperations supervisorDocumentAlways
Electrical Safety Officer annual inspection and test reportOperations supervisorDocumentAlways
Annual review and erasure of personal data no longer neededOperations supervisorChecklistAlways
Annual crèche facility reviewManagerChecklistAlways

6. Things you log when they happen

These have no fixed date. Log them in the app on the day they happen, so the record is made at the time and not rebuilt later.

WhatWhenUsually logged byNeeded
Unplanned refrigerant leak event logEach time it happensChiller / HVAC engineerAlways
E-waste handover receipt from registered producer/refurbisher/recyclerEach time it happensOperations supervisorAlways
Certificate of destruction / processing certificate (where provided)Each time it happensOperations supervisorAlways
Spent battery handover receipt / take-back confirmationEach time it happensOperations supervisorAlways
EPR take-back confirmation from vendor at battery replacementEach time it happensOperations supervisorAlways
Per-event banquet SUP-free vendor checkEach time it happensOperations supervisorAlways
Common area event PA/loudspeaker compliance declarationEach time it happensOperations supervisorAlways
C&D waste dispatch to authorized processor receiptEach time it happensOperations supervisorIf C&D Waste Management Rules 2025 applies
ULB vehicle handover receiptEach time it happensHousekeeping / floor staffAlways
HWM Form 10 dispatch manifest (per hazardous dispatch)Each time it happensOperations supervisorIf HWM Rules 2016 applies
Adhoc e-waste handover to authorised recycler (single event)Each time it happensHousekeeping / floor staffIf Periodic E-Waste Handover Log to Authorised Recycler applies
DG run log entry (per operation) (each DG set)Each time it happensDG / power engineerIf Air Act 1981 applies
BS-VI ULSD fuel purchase invoiceEach time it happensDG / power engineerIf Air Act 1981 applies
Faecal sludge transport manifest / FSTP receipt (each septic tank)Each time it happensOperations supervisorAlways
HVAC service log entry (per service event)Each time it happensHousekeeping / floor staffAlways
Refrigerant recovery certificate at decommissioningEach time it happensManagerAlways
Lift accident report to the inspectorEach time it happensOperations supervisorIf Lifts & escalators applies
Electrical accident intimationEach time it happensOperations supervisorAlways
Workplace accident / dangerous occurrence noticeEach time it happensOperations supervisorAlways
Personal data breach intimationEach time it happensManagerAlways
End-of-life solar panels handed only to a registered recycler or the producerEach time it happensManagerAlways

7. Licence renewals

Enter the expiry date of each licence when you upload it. The app then creates the renewal job ahead of the expiry, so nobody has to remember the date.

RenewalOwnerNeeded
STP CTO renewal taskCompliance officerAlways
FSSAI licence renewal task (pre-expiry)Compliance officerAlways
CGWA NOC renewal taskCompliance officerIf CGWA Groundwater Rules applies
Fire NOC renewal taskCompliance officerAlways
PESO licence renewal taskCompliance officerIf Petroleum Act + PESO applies
HWM authorisation renewal taskCompliance officerIf HWM Rules 2016 applies
Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)Compliance officerAlways
SPCB DG set CTO renewal taskCompliance officerIf Air Act 1981 applies
Lift licence / registration — renewalManagerIf Lifts & escalators applies
Lift maintenance contract (AMC) — renewalManagerIf Lifts & escalators applies
Lift third-party insurance — renewalManagerIf Lifts & escalators applies
Electrical installation inspection / self-certification — renewalManagerAlways
Municipal trade / health trade licence — renewalManagerIf Trade licence applies
Structural stability certificate — renewalManagerAlways
Contractor labour licences (50 or more contract workers) — renewalManagerAlways
Security agency licence (PSARA) — renewalManagerAlways
LPG approval renewal taskManagerAlways
Piped natural gas (PNG) installation third-party safety certificate — renewalManagerAlways
Pest-control operator's licence (Insecticides Rules 1971) — renewalManagerAlways

8. Your filing calendar

Filings are statutory returns you submit to a regulator. The app reminds the owner ahead of each due date and collects the figures from the jobs your team has done through the year, so the return is built from real records.

FilingDueWhereRuleNeeded
SWM Annual Return30 June every year–SWM Rules 2026Always
HWM Form 4 Annual Return30 June every year–HWM Rules 2016If the rule applies
BRSR Annual Report30 September every year–BRSR / SEBIIf the rule applies
CGWA Groundwater Abstraction & Compliance Data Submission10th of every monthCGWA Bhu-Neer portal (cgwa-bhuneer.mowr.gov.in)CGWA Groundwater RulesIf the rule applies
DG Stack Emission Report Submission to SPCB30 June every yearState SPCB portalAir Act 1981If the rule applies
PWM EPR ANNUAL RETURN30 June every year–Plastic Waste Management Rules, 2016 (as amended)Always
FSSAI Annual Fee + FSCR Filing31 March every yearFoSCoSFSSAI Act 2006Always
Environmental Statement (Form V)30 September every yearState SPCB portalEnvironmental Statement (Form V)If the rule applies

9. The rules behind all this

Applies to every site of this type

RuleWhat it asks of you
E-Waste Management Rules 2022
Battery Waste Management Rules 2022
ODS Rules 2000
SWM Rules 2026
Plastic Waste Management Rules, 2016 (as amended)
FSSAI Act 2006
Water Act 1974 / STP
Noise Pollution Rules 2000

Depends on what is on your site

RuleWhat it asks of you
Air Act 1981
CGWA Groundwater Rules
HWM Rules 2016
Petroleum Act + PESO
BRSR / SEBI
C&D Waste Management Rules 2025
Dry Recyclable Sale to Authorized Buyer
UCO (Used Cooking Oil) Handover to Authorised RUCO Aggregator
Periodic E-Waste Handover Log to Authorised Recycler
POSH Internal Complaints CommitteeAny workplace with 10 or more employees must proactively constitute an Internal Complaints Committee, including an external member, at every branch or office location — waiting until a complaint arises is itself a violation.
Lifts & escalatorsA lift runs on a licence and a maintenance contract that both expire. Where the state has a lift Act you get its statutory tests and filings; everywhere you get monthly maintenance, rescue-device checks and an accident log, because the owner answers for a defect that was known and not fixed.
Trade licenceHotels, restaurants, hospitals, shops and most commercial premises need a trade licence from the local body, and it is often a prerequisite for other licences and utility connections.
Environmental Statement (Form V)If your premises runs under an SPCB consent to operate (for an STP, ETP, DG set or boiler) or a hazardous-waste authorisation, you owe the Board a yearly environmental statement — water and raw-material use, pollutants discharged, hazardous and solid waste generated, and measures taken. It is easy to miss because no renewal prompts it.
Environmental Clearance (EIA)Projects near sensitive ecosystems or within 10km of a protected area need prior Environmental Clearance before construction begins.
Rainwater harvestingWhere the state binds existing buildings, a missing or non-working structure is a standing violation and can raise the water bill; elsewhere it is the approval-time condition most often left unmaintained.
Swimming poolA pool is where a lapse turns into a drowning or an infection. Daily water tests and a lifeguard and equipment check are the records that show it was run safely; in Tamil Nadu they are law.
EV Charging SafetyChargers in shared parking need a commissioning certificate and periodic electrical safety inspection, earthing checks and load management.
RuleWhat it asks of you
Fire Safety / NBC / IT Park Occupancy
Shops & Establishments RegistrationNearly every commercial or institutional premises operating in India needs Shops & Establishments registration from the state labour department or municipal corporation — this is separate from any sector-specific licence and applies regardless of business type.
Electrical safetyEvery premises has an electrical installation that needs a current inspection or self-certification. Most fires in buildings start electrically, and a lapsed inspection is the first thing an insurer or investigator asks for.
Occupancy & structureThe occupancy certificate is the document other licences ask for; in Maharashtra and Gujarat an older building also needs a current structural stability certificate.
Site labour dutiesThese are the labour duties that show up on site — a stocked first-aid box, an accident notice, and proof that the agencies supplying your housekeeping and security staff are licensed. Wages, provident fund and ESI stay with payroll.
Personal data protectionResident, visitor, guest, patient, student and staff records — and CCTV — are personal data. The core duties start on 13 May 2027; these tasks get the notice, breach plan and grievance contact in place before then.

This guide explains how the app helps you keep records. It is not legal advice; your regulator's notification is the final word.

10. Job sheets for each person

Print the section for each person and hand it over with their login. It lists only the jobs that are usually theirs; their role guide explains how to do any job in the app.

Manager

Every six months

  • 6-monthly EC compliance report (if EC granted) (only if Environmental Clearance (EIA) applies)

Every year

  • Kitchen staff annual health certificate
  • Annual HSD tank integrity inspection (only if Petroleum Act + PESO applies)
  • Green/recycled-content procurement record
  • Environmental Statement (Form V) to the SPCB (30 September) (only if Environmental Statement (Form V) applies)
  • Annual crèche facility review

Each time it happens

  • Refrigerant recovery certificate at decommissioning
  • Personal data breach intimation
  • End-of-life solar panels handed only to a registered recycler or the producer

Before the licence expires

  • Lift licence / registration — renewal (each lift) (only if Lifts & escalators applies)
  • Lift maintenance contract (AMC) — renewal (only if Lifts & escalators applies)
  • Lift third-party insurance — renewal (only if Lifts & escalators applies)
  • Electrical installation inspection / self-certification — renewal
  • Municipal trade / health trade licence — renewal (only if Trade licence applies)
  • Structural stability certificate — renewal
  • Contractor labour licences (50 or more contract workers) — renewal
  • Security agency licence (PSARA) — renewal
  • LPG approval renewal task
  • Piped natural gas (PNG) installation third-party safety certificate — renewal
  • Pest-control operator's licence (Insecticides Rules 1971) — renewal

How to do these in the app: Manager guide.

Compliance officer (Manager access)

Every week

  • Weekly dry recyclable sale / handover to authorized buyer (only if Dry Recyclable Sale to Authorized Buyer applies)

Every month

  • CGWA abstraction and compliance data submission (only if CGWA Groundwater Rules applies)
  • Pool chemical waste disposal log (only if HWM Rules 2016 / Swimming pool applies)

Every six months

  • Half-yearly drinking water quality test (IS 10500)
  • 6-monthly certified fire system inspection (IS 2190)

Every year

  • Annual tenant-level ESG data collection for BRSR reporting (only if BRSR / SEBI applies)
  • Annual BRSR environmental data compilation (only if BRSR / SEBI applies)
  • Annual Scope 1/2/3 GHG calculation report (only if BRSR / SEBI applies)
  • BRSR section in Annual Report (published) (only if BRSR / SEBI applies)
  • SWM Annual Return (if BWG)
  • Annual refrigerant top-up review and leak audit
  • HWM Form 4 annual return (June 30) (only if HWM Rules 2016 applies)
  • Annual CPCB PWM EPR return
  • Annual fire system service / hydro-test (IS 2190)
  • POSH annual report to District Officer (only if POSH Internal Complaints Committee applies)
  • 2-year STP installation plan / approval (no on-site STP)

Before the licence expires

  • FSSAI licence renewal task (pre-expiry)
  • CGWA NOC renewal task (only if CGWA Groundwater Rules applies)
  • Fire NOC renewal task
  • PESO licence renewal task (only if Petroleum Act + PESO applies)
  • HWM authorisation renewal task (only if HWM Rules 2016 applies)
  • Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)

Before the licence expires

  • STP CTO renewal task (each STP)
  • SPCB DG set CTO renewal task (only if Air Act 1981 applies)

How to do these in the app: Manager guide.

Chiller / HVAC engineer (Supervisor access)

Each time it happens

  • Unplanned refrigerant leak event log

How to do these in the app: Supervisor guide.

DG / power engineer (Supervisor access)

Every year

  • Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set) (only if Air Act 1981 applies)
  • Stack emission test report submission to SPCB (only if Air Act 1981 applies)

Each time it happens

  • DG run log entry (per operation) (each DG set) (only if Air Act 1981 applies)
  • BS-VI ULSD fuel purchase invoice (only if Air Act 1981 applies)

How to do these in the app: Supervisor guide.

Tenant compliance liaison (Supervisor access)

Every year

  • Annual audit that all food court / cafeteria tenants hold valid FSSAI license

How to do these in the app: Supervisor guide.

Operations supervisor (Supervisor access)

Every day

  • Daily pool water pH and free chlorine log (only if Swimming pool applies)

Every week

  • No unauthorized C&D dumping declaration (only if C&D Waste Management Rules 2025 applies)
  • Weekly segregation spot check (each floor)

Every month

  • Monthly no-open-burning declaration
  • Monthly single-use plastic ban audit
  • Dry plastic waste to authorized recycler
  • Monthly STP effluent quality test (each STP)
  • No effluent to groundwater declaration
  • Fire system maintenance (extinguishers, hydrants, sprinklers)
  • HWM storage inspection (≤90 days, no mixing) (only if HWM Rules 2016 applies)
  • Monthly rainwater harvesting structure maintenance log (each rainwater pit) (only if CGWA Groundwater Rules / Rainwater harvesting applies)
  • Monthly lift maintenance visit (each lift) (only if Lifts & escalators applies)
  • Monthly first-aid box check
  • Used engine oil handover to a registered collection agent / recycler (only if HWM Rules 2016 applies)
  • Monthly pool lifeguard and safety equipment check (only if Swimming pool applies)
  • Cooling tower blowdown water quality and disposal log

Every quarter

  • Quarterly data centre / UPS room / DG room fire safety check
  • Quarterly fire escape signage and emergency lighting check
  • Fire drill and staff evacuation training record
  • Quarterly lift test by a registered person (each lift) (only if Lifts & escalators applies)
  • Lift rescue device, alarm and intercom check (each lift) (only if Lifts & escalators applies)
  • Quarterly EV charging bay electrical safety inspection (only if EV Charging Safety applies)
  • Quarterly LPG/CNG gas installation safety check

Every six months

  • Six-monthly lift test by an authorised person (each lift) (only if Lifts & escalators applies)
  • Lift rescue mock drill (only if Lifts & escalators applies)

Every year

  • Annual pre-monsoon groundwater quality test (each borewell) (only if CGWA Groundwater Rules applies)
  • Annual noise level test at property boundary
  • Fuel storage area fire safety check (only if Petroleum Act + PESO applies)
  • Annual lift safety certificate / inspection report (only if Lifts & escalators applies)
  • Annual earth resistance test
  • Electrical Safety Officer annual inspection and test report
  • Annual review and erasure of personal data no longer needed

Each time it happens

  • E-waste handover receipt from registered producer/refurbisher/recycler
  • Certificate of destruction / processing certificate (where provided)
  • Spent battery handover receipt / take-back confirmation
  • EPR take-back confirmation from vendor at battery replacement
  • Per-event banquet SUP-free vendor check
  • Common area event PA/loudspeaker compliance declaration
  • C&D waste dispatch to authorized processor receipt (only if C&D Waste Management Rules 2025 applies)
  • HWM Form 10 dispatch manifest (per hazardous dispatch) (only if HWM Rules 2016 applies)
  • Faecal sludge transport manifest / FSTP receipt (each septic tank)
  • Lift accident report to the inspector (only if Lifts & escalators applies)
  • Electrical accident intimation
  • Workplace accident / dangerous occurrence notice

How to do these in the app: Supervisor guide.

Housekeeping / floor staff (Worker access)

Every day

  • Daily waste weighment log
  • Food and garden waste composting / processing log
  • Daily garden/leaf waste composting or disposal log
  • Daily C&D waste volume log by category (only if C&D Waste Management Rules 2025 applies)
  • Daily borewell pump run log (each borewell) (only if CGWA Groundwater Rules applies)

Every week

  • On-site C&D waste segregation zone photo (4-category) (only if C&D Waste Management Rules 2025 applies)
  • Weekly groundwater abstraction log (per borewell) (each borewell) (only if CGWA Groundwater Rules applies)

Every month

  • Monthly check — no e-waste in general waste bins
  • Monthly check — no batteries in general waste
  • Dry waste dispatch to authorized recycler
  • STP sludge disposal log (each STP)
  • UCO handover to FSSAI-registered aggregator
  • Monthly STP performance log (each STP)
  • Treated effluent reuse log (gardening/flushing) (each STP)
  • Monthly groundwater level monitoring (each borewell) (only if CGWA Groundwater Rules applies)
  • Plastic waste segregation log (dry stream + MLP tracking)
  • Sanitary waste stream handover log (SWM 2026)
  • Special-care waste stream handover log (SWM 2026)
  • Septic tank / cesspool desludging log (each septic tank)

Every quarter

  • Periodic e-waste handover log to authorised recycler (only if Periodic E-Waste Handover Log to Authorised Recycler applies)

Each time it happens

  • ULB vehicle handover receipt
  • Adhoc e-waste handover to authorised recycler (single event) (only if Periodic E-Waste Handover Log to Authorised Recycler applies)
  • HVAC service log entry (per service event)

How to do these in the app: Worker guide.

Kitchen supervisor (Supervisor access)

Every day

  • PM POSHAN / MDM daily quality inspection and tasting record

Every month

  • Monthly Schedule 4 hygiene inspection
  • Pest control treatment record

Every year

  • FSSAI annual fee payment + Food Safety Compliance Report (FSCR) filing

How to do these in the app: Supervisor guide.