Browse all help

Guides

How do I…?

Signing in and the app7
Doing jobs13
Checking jobs and running the team10
Setting up and managing17
Collection, intake and gate7

By type of organisation

De-addiction / Rehabilitation Centre: setup and training guide

On this page

This page is the part of the onboarding kit that is specific to a De-addiction / Rehabilitation Centre. It lists what the app will set up for you, who in your team normally does each piece, and what you need to have ready. How to use the app is in the shared guides, which are the same for every organisation:

The lists below come from the same rule set the app uses, so they match what you will see. What actually applies to your site depends on your answers during setup: a rule marked "depends on your site" is only switched on if you have, for example, a borewell or a kitchen.

1. At a glance

WhatHow many (maximum)
Rules that apply to every De-addiction6
Rules that depend on what is on your site15
Good-practice rules (recommended)6
One-time setup items (photos, documents, certificates)56
Recurring jobs (daily to yearly)53
Things you log when they happen14
Licence renewals tracked18
Statutory filings5

Most sites end up with fewer than the maximum, because the setup questions switch off what does not apply.

2. Who you need on the app

Each row is a job in your organisation, not necessarily a separate person. In a small site one person often holds several rows: the manager is usually also the compliance officer. Every person signs in with their own account, so the record shows who did what.

RoleApp accessWhat they look afterNeeded?Items they own
Medical directorManagerStatutory responsible person for the facility authorisation.Yes–
ManagerManagerAdministratorYes10
Bio-medical waste coordinatorManagerclinical wasteYes6
Housekeeping / floor staffWorkerCare StaffYes15
Compliance officerManagerSPCB / NDPS liaisonYes68
Nurse / ward in-chargeSupervisorWard BMW daily logsYes15
Pharmacy in-chargeSupervisorNDPS stock / pharmacyYes1
Kitchen supervisorSupervisorResidential kitchen FSSAIYes3
Operations supervisorSupervisorFacility operations coordination, hygiene/dispatch spot checksYes28

App access decides what a person sees. Manager: the web portal and the phone app, with setup, approvals, reports and filings. Supervisor: the phone app, with their team's jobs and approvals. Worker: the phone app, with their own jobs only.

3. Before setup: have these ready

Questions the setup will ask about your site

Setup takes about 30 to 45 minutes if you have these answers to hand. "Not sure" is fine for anything you can find out later; you can change answers afterwards.

Numbers

  • Number of diesel generators on site
  • Diesel/fuel storage capacity on site
  • Number of lifts
  • Number of escalators / moving walks
  • Connected electrical load (kW)
  • Age of the building (years)
  • Contract workers engaged through contractors
  • Plot area (sq m)
  • Solar plant capacity (kW)
  • Number of employees / workers on site

Yes or no

  • Bulk Waste Generator (meets waste-quantity threshold requiring registration)?
  • Borewell / groundwater extraction on premises?
  • Electrical/electronic equipment on premises?
  • UPS/inverter batteries on premises?
  • On-site sewage treatment plant (STP)?
  • Active renovation on site?
  • Rainwater harvesting on site?
  • Employs 10 or more people (incl. contract/interns)?
  • Clinical Establishments (Registration and Regulation) Act, 2010 applies in this state (some states use their own separate Act instead)?
  • Uses septic tank / storage tank (no onsite STP)?
  • Local body requires a trade licence?
  • Security guards supplied by an agency?
  • Holds an SPCB consent (Water / Air Act) or hazardous-waste authorisation?
  • On-site medical care / dispensary (detox medication, injections)?
  • State law requires rainwater harvesting here (derived from state and plot area; not asked)?
  • Rooftop / ground-mounted solar plant on site?

Other details

  • No-STP wastewater scenario

Documents and licences to gather

Collect what you already have as PDFs or clear phone photos. Anything you do not have yet stays on your list as a gap; it does not block setup.

DocumentNeeded
☐ Mental Healthcare Act / state de-addiction facility registrationAlways
☐ NDPS/State Drug Controller authorization for controlled substance dispensingAlways
☐ NDPS record retention compliance (2-year retention policy)Always
☐ BMW SPCB/PCC authorization certificateAlways
☐ FSSAI food business license (Registration/State/Central)Always
☐ Fire Safety NOC from State Fire ServiceAlways
☐ CPCB BWG portal registrationAlways
☐ CGWA NOC or exemption certificateIf Groundwater Extraction (CGWA) applies
☐ STP Consent to Operate from SPCB (each STP)If Sewage Treatment Plant (STP) Consent applies
☐ PESO petroleum storage licenseIf Diesel Storage Licence (PESO) applies
☐ C&D Waste Management PlanIf Construction & Demolition (C&D) Waste applies
☐ ULB approval/intimation for large C&D projectsIf Construction & Demolition (C&D) Waste applies
☐ Rainwater harvesting system installation certificate (each rainwater pit)If Groundwater Extraction (CGWA) / Rainwater harvesting applies
☐ Diesel generator (DG) exhaust stack height compliance certificate (each DG set)If Diesel Generator (DG) Air & Noise Norms applies
☐ SPCB Consent to Operate (CTO) for diesel generator (DG)If Diesel Generator (DG) Air & Noise Norms applies
☐ Shops & Establishments Act registrationAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)If POSH Internal Complaints Committee applies
☐ Clinical Establishment Authority registration certIf Clinical Establishment Registration applies
☐ Waste management plan (submission to state authority)If Clinical Establishment Registration applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)Always
☐ Lift licence / registration (each lift)If Lifts & escalators applies
☐ Lift maintenance contract (AMC)If Lifts & escalators applies
☐ Lift third-party insuranceIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationAlways
☐ Electrical Safety Officer appointmentAlways
☐ Fire-safe wiring and supply isolation certificateAlways
☐ Municipal trade / health trade licenceIf Trade licence applies
☐ Occupancy / completion certificateAlways
☐ Structural stability certificateAlways
☐ Contractor labour licences (50 or more contract workers)Always
☐ Security agency licence (PSARA)Always
☐ Privacy notice for residents / visitors / customers / staffAlways
☐ Personal data breach response planAlways
☐ SPCB HWM authorizationIf Hazardous Waste (HWM Rules 2016) applies
☐ Electrical Inspector approval of the rooftop solar plantAlways
☐ Self-certification of the rooftop solar plantAlways
☐ Net-metering / grid connection agreement with the discomAlways
☐ Crèche facility for employees' children (50 or more employees)Always

4. Setup evidence: your first-weeks checklist

Setup evidence is the one-time proof of what is on your site: a photo of each bin, the STP nameplate, a copy of each licence. After setup each item appears as a job under Setup Evidence. Photo items for equipment start with a scan of that item's QR sticker, so stick the stickers on first (see Setup evidence and QR stickers).

Compliance officer

ItemEvidenceNeeded
☐ Mental Healthcare Act / state de-addiction facility registrationCertificateAlways
☐ BMW SPCB/PCC authorization certificateCertificateAlways
☐ FSSAI food business license (Registration/State/Central)CertificateAlways
☐ Fire Safety NOC from State Fire ServiceCertificateAlways
☐ CPCB BWG portal registrationCertificateAlways
☐ CGWA NOC or exemption certificateCertificateIf Groundwater Extraction (CGWA) applies
☐ STP Consent to Operate from SPCB (each STP)CertificateIf Sewage Treatment Plant (STP) Consent applies
☐ PESO petroleum storage licenseCertificateIf Diesel Storage Licence (PESO) applies
☐ ULB approval/intimation for large C&D projectsDocumentIf Construction & Demolition (C&D) Waste applies
☐ Diesel generator (DG) exhaust stack height compliance certificate (each DG set)DocumentIf Diesel Generator (DG) Air & Noise Norms applies
☐ SPCB Consent to Operate (CTO) for diesel generator (DG)CertificateIf Diesel Generator (DG) Air & Noise Norms applies
☐ Shops & Establishments Act registrationCertificateAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)DocumentIf POSH Internal Complaints Committee applies
☐ Clinical Establishment Authority registration certCertificateIf Clinical Establishment Registration applies
☐ Waste management plan (submission to state authority)DocumentIf Clinical Establishment Registration applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)CertificateAlways
☐ Lift / escalator nameplate photo (each lift)PhotoIf Lifts & escalators applies
☐ Lift licence / registration (each lift)CertificateIf Lifts & escalators applies
☐ Lift maintenance contract (AMC)CertificateIf Lifts & escalators applies
☐ Lift third-party insuranceCertificateIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationCertificateAlways
☐ Electrical Safety Officer appointmentDocumentAlways
☐ Fire-safe wiring and supply isolation certificateDocumentAlways
☐ Municipal trade / health trade licenceCertificateIf Trade licence applies
☐ Occupancy / completion certificateCertificateAlways
☐ Structural stability certificateCertificateAlways
☐ Contractor labour licences (50 or more contract workers)CertificateAlways
☐ Security agency licence (PSARA)CertificateAlways
☐ Privacy notice for residents / visitors / customers / staffDocumentAlways
☐ Named contact for personal-data grievancesDeclarationAlways
☐ Personal data breach response planDocumentAlways
☐ SPCB HWM authorizationCertificateIf Hazardous Waste (HWM Rules 2016) applies
☐ Electrical Inspector approval of the rooftop solar plantDocumentAlways
☐ Self-certification of the rooftop solar plantDocumentAlways
☐ Net-metering / grid connection agreement with the discomDocumentAlways
☐ Crèche facility for employees' children (50 or more employees)DocumentAlways

Bio-medical waste coordinator

ItemEvidenceNeeded
☐ NDPS/State Drug Controller authorization for controlled substance dispensingCertificateAlways
☐ NDPS record retention compliance (2-year retention policy)DocumentAlways

Housekeeping / floor staff

ItemEvidenceNeeded
☐ BMW color-coded bin setup photo (each ward)PhotoAlways

Manager

ItemEvidenceNeeded
☐ Bin overview photo (position, label & lid) — per bin (each bin)PhotoAlways
☐ Secondary containment (bunding) photoPhotoIf Diesel Storage Licence (PESO) applies
☐ C&D Waste Management PlanDocumentIf Construction & Demolition (C&D) Waste applies
☐ Rainwater harvesting system installation certificate (each rainwater pit)DocumentIf Groundwater Extraction (CGWA) / Rainwater harvesting applies
☐ STP full installation overview (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ Consent-to-Operate document displayed near STP (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ Composting unit full overview (each compost unit)PhotoAlways
☐ Diesel generator (DG) set — full installation overview (each DG set)PhotoIf Diesel Generator (DG) Air & Noise Norms applies

Operations supervisor

ItemEvidenceNeeded
☐ Four-stream segregation signage and bin infrastructure photoPhotoAlways
☐ STP capacity nameplate or equipment label (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ STP inlet connection from building drainage (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ STP outlet pipe destination connection (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ STP sludge disposal / drying area (each STP)PhotoIf Sewage Treatment Plant (STP) Consent applies
☐ Composting unit capacity label (each compost unit)PhotoAlways
☐ Compost output storage area (each compost unit)PhotoAlways
☐ Diesel generator (DG) capacity nameplate (each DG set)PhotoIf Diesel Generator (DG) Air & Noise Norms applies

Nurse / ward in-charge

ItemEvidenceNeeded
☐ Electrical danger notices and shock-treatment chartPhotoAlways

5. Your recurring jobs

These are created automatically once setup is done and come back on their own schedule. Each shows on the phone of the person it is assigned to. The "Usually done by" column is the default; the manager can reassign any job (see Manager guide).

Every day

JobUsually done byEvidenceNeeded
NDPS controlled substance daily stock/dispensing/balance registerBio-medical waste coordinatorDocumentAlways
BMW daily generation log by enabled categoryNurse / ward in-chargeReadingsAlways
Daily waste log by stream (weigh on collection days)Housekeeping / floor staffReadingsAlways
Daily organic waste processing log (Option A)Housekeeping / floor staffReadingsAlways
Daily C&D waste volume log by categoryHousekeeping / floor staffReadingsIf Construction & Demolition (C&D) Waste applies
Daily borewell pump run log (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies

Every week

JobUsually done byEvidenceNeeded
On-site C&D waste segregation zone photo (4-category)Housekeeping / floor staffPhotoIf Construction & Demolition (C&D) Waste applies
No unauthorized C&D dumping declarationOperations supervisorDeclarationIf Construction & Demolition (C&D) Waste applies
Weekly groundwater abstraction log (per borewell) (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies

Every month

JobUsually done byEvidenceNeeded
Monthly minimum standards compliance check (staffing, patient rights, emergency care)Compliance officerChecklistAlways
FSSAI Schedule 4 monthly hygiene inspectionKitchen supervisorChecklistAlways
UCO handover to FSSAI-registered UCO aggregatorKitchen supervisorDocumentAlways
Monthly single-use plastic ban auditOperations supervisorChecklistAlways
Plastic waste dispatch to CPCB-authorized recyclerOperations supervisorDocumentAlways
Fire system maintenance (extinguishers, hydrants, sprinklers)Operations supervisorDocumentAlways
Monthly no-open-burning declarationOperations supervisorDeclarationAlways
Monthly groundwater level monitoring (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies
Monthly STP performance log (each STP)Housekeeping / floor staffReadingsIf Sewage Treatment Plant (STP) Consent applies
Monthly STP effluent quality test (each STP)Operations supervisorDocumentIf Sewage Treatment Plant (STP) Consent applies
Treated effluent reuse log (gardening/flushing) (each STP)Housekeeping / floor staffReadingsIf Sewage Treatment Plant (STP) Consent applies
STP sludge disposal log (each STP)Housekeeping / floor staffDocumentIf Sewage Treatment Plant (STP) Consent applies
No effluent to groundwater declarationOperations supervisorDeclarationIf Sewage Treatment Plant (STP) Consent applies
Sanitary waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Special-care waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Monthly rainwater harvesting structure maintenance log (each rainwater pit)Operations supervisorDocumentIf Groundwater Extraction (CGWA) / Rainwater harvesting applies
Septic tank / cesspool desludging log (each septic tank)Housekeeping / floor staffDocumentIf Sewage Treatment Plant (STP) Consent applies
Monthly lift maintenance visit (each lift)Nurse / ward in-chargeChecklistIf Lifts & escalators applies
Monthly first-aid box checkNurse / ward in-chargeChecklistAlways
Used engine oil handover to a registered collection agent / recyclerOperations supervisorReadingsIf Hazardous Waste (HWM Rules 2016) applies

Every quarter

JobUsually done byEvidenceNeeded
Quarterly fire escape signage and emergency lighting checkOperations supervisorPhotoAlways
Fire drill and staff evacuation training recordOperations supervisorDocumentAlways
Quarterly lift test by a registered person (each lift)Nurse / ward in-chargeDocumentIf Lifts & escalators applies
Lift rescue device, alarm and intercom check (each lift)Nurse / ward in-chargeChecklistIf Lifts & escalators applies

Every six months

JobUsually done byEvidenceNeeded
BMW segregation and handling staff trainingBio-medical waste coordinatorDocumentAlways
6-monthly certified fire system inspection (IS 2190)Compliance officerDocumentAlways
Six-monthly lift test by an authorised person (each lift)Nurse / ward in-chargeDocumentIf Lifts & escalators applies
Lift rescue mock drillNurse / ward in-chargeDocumentIf Lifts & escalators applies

Every year

JobUsually done byEvidenceNeeded
Food handling staff annual medical fitness certificatesManagerDocumentAlways
Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set)Operations supervisorDocumentIf Diesel Generator (DG) Air & Noise Norms applies
Annual noise level test at property boundaryOperations supervisorDocumentIf Noise Pollution Rules applies
Annual HSD tank integrity inspectionManagerDocumentIf Diesel Storage Licence (PESO) applies
Fuel storage area fire safety checkOperations supervisorChecklistIf Diesel Storage Licence (PESO) applies
Annual fire system service / hydro-test (IS 2190)Compliance officerDocumentAlways
POSH annual report to District OfficerCompliance officerDocumentIf POSH Internal Complaints Committee applies
Annual waste generation report to State Health AuthorityCompliance officerDocumentIf Clinical Establishment Registration applies
2-year STP installation plan / approval (no on-site STP)Compliance officerDocumentIf Sewage Treatment Plant (STP) Consent applies
Annual lift safety certificate / inspection reportNurse / ward in-chargeDocumentIf Lifts & escalators applies
Annual earth resistance testNurse / ward in-chargeDocumentAlways
Electrical Safety Officer annual inspection and test reportNurse / ward in-chargeDocumentAlways
Annual review and erasure of personal data no longer neededNurse / ward in-chargeChecklistAlways
Hepatitis B and tetanus immunisation of staff handling bio-medical wasteOperations supervisorChecklistAlways
Health check-up of staff handling bio-medical wasteOperations supervisorDocumentAlways
Annual crèche facility reviewCompliance officerChecklistAlways

6. Things you log when they happen

These have no fixed date. Log them in the app on the day they happen, so the record is made at the time and not rebuilt later.

WhatWhenUsually logged byNeeded
Patient-surrendered drugs on admission — formal surrender recordEach time it happensBio-medical waste coordinatorAlways
CBWTF barcode-scan / handover record per collection visitEach time it happensBio-medical waste coordinatorAlways
Expired/recalled non-cytotoxic medicine disposal logEach time it happensPharmacy in-chargeAlways
E-waste handover receipt from registered producer/refurbisher/recyclerEach time it happensOperations supervisorIf E-Waste Management applies
Spent battery handover receipt / take-back confirmationEach time it happensOperations supervisorIf Battery Waste Management applies
DG run log entry (per operation) (each DG set)Each time it happensHousekeeping / floor staffIf Diesel Generator (DG) Air & Noise Norms applies
C&D waste dispatch to authorized processor receiptEach time it happensOperations supervisorIf Construction & Demolition (C&D) Waste applies
Faecal sludge transport manifest / FSTP receipt (each septic tank)Each time it happensOperations supervisorIf Sewage Treatment Plant (STP) Consent applies
Lift accident report to the inspectorEach time it happensNurse / ward in-chargeIf Lifts & escalators applies
Electrical accident intimationEach time it happensNurse / ward in-chargeAlways
Workplace accident / dangerous occurrence noticeEach time it happensNurse / ward in-chargeAlways
Personal data breach intimationEach time it happensCompliance officerAlways
Bio-medical waste accident report (Form I)Each time it happensCompliance officerAlways
End-of-life solar panels handed only to a registered recycler or the producerEach time it happensCompliance officerIf E-Waste Management applies

7. Licence renewals

Enter the expiry date of each licence when you upload it. The app then creates the renewal job ahead of the expiry, so nobody has to remember the date.

RenewalOwnerNeeded
STP CTO renewal taskCompliance officerIf Sewage Treatment Plant (STP) Consent applies
BMW authorisation renewal taskCompliance officerAlways
FSSAI licence renewal task (pre-expiry)Compliance officerAlways
CGWA NOC renewal taskCompliance officerIf Groundwater Extraction (CGWA) applies
PESO licence renewal taskCompliance officerIf Diesel Storage Licence (PESO) applies
Fire NOC renewal taskCompliance officerAlways
SPCB DG set CTO renewal taskCompliance officerIf Diesel Generator (DG) Air & Noise Norms applies
Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)Compliance officerAlways
Clinical Establishment registration renewal task (permanent registration, 5-year validity)Compliance officerIf Clinical Establishment Registration applies
Lift licence / registration — renewalCompliance officerIf Lifts & escalators applies
Lift maintenance contract (AMC) — renewalCompliance officerIf Lifts & escalators applies
Lift third-party insurance — renewalCompliance officerIf Lifts & escalators applies
Electrical installation inspection / self-certification — renewalCompliance officerAlways
Municipal trade / health trade licence — renewalCompliance officerIf Trade licence applies
Structural stability certificate — renewalCompliance officerAlways
Contractor labour licences (50 or more contract workers) — renewalCompliance officerAlways
Security agency licence (PSARA) — renewalCompliance officerAlways
HWM authorisation renewal taskCompliance officerIf Hazardous Waste (HWM Rules 2016) applies

8. Your filing calendar

Filings are statutory returns you submit to a regulator. The app reminds the owner ahead of each due date and collects the figures from the jobs your team has done through the year, so the return is built from real records.

FilingDueWhereRuleNeeded
BMW ANNUAL RETURN30 June every year–BMW 2016Always
SWM ANNUAL RETURN30 June every year–Solid Waste Management (SWM) 2026Always
FSSAI Annual Fee + FSCR Filing31 March every yearFoSCoSFSSAIAlways
Environmental Statement (Form V)30 September every yearState SPCB portalEnvironmental Statement (Form V)If the rule applies
HWM Form 4 Annual Return30 June every yearState SPCB portalHazardous Waste (HWM Rules 2016)If the rule applies

9. The rules behind all this

Applies to every site of this type

RuleWhat it asks of you
BMW 2016
DRUGS NDPS
Mental Health Establishment RegistrationThis facility must register as a Mental Health Establishment with the State/Central Mental Health Authority, meeting minimum standards for space, staff qualifications, and record-keeping.
FSSAI
Plastic Waste ManagementCovers segregating plastic waste, the single-use-plastic ban, and handing dry plastic over to authorised recyclers — applies regardless of org size.
Solid Waste Management (SWM) 2026Requires segregating waste into 4 streams (wet/dry/sanitary/special-care), registering as a Bulk Waste Generator, and either composting wet waste on-site or obtaining an EBWGR certificate from the local body.

Depends on what is on your site

RuleWhat it asks of you
Groundwater Extraction (CGWA)If groundwater is drawn from a borewell/tube well, CGWA requires monthly groundwater-level monitoring reported through their portal.
E-Waste ManagementE-waste (UPS batteries, old electronics, lighting) must go only to a registered recycler — no separate CPCB registration is needed as a bulk consumer.
Battery Waste ManagementUPS/inverter batteries and other battery waste must be segregated and handed to an authorised collector, not thrown out with general waste.
Diesel Generator (DG) Air & Noise NormsRunning a diesel generator for power backup needs SPCB consent, an acoustic enclosure, and periodic stack-emission testing.
Noise Pollution RulesLimits DG-set and loudspeaker noise, including a 10pm-6am night restriction — enforced by the District Magistrate/Police, not SPCB.
Sewage Treatment Plant (STP) ConsentOperating an on-site STP needs SPCB Consent to Operate plus monthly performance and sludge-disposal logs.
Diesel Storage Licence (PESO)Storing more than 2,500L of diesel for DG backup requires a PESO storage licence and periodic tank safety certification.
Construction & Demolition (C&D) WasteAny renovation or demolition work must segregate C&D waste per the local authority's plan; projects over 20,000 sq.m also need EPR portal registration.
POSH Internal Complaints CommitteeAny workplace with 10 or more employees must proactively constitute an Internal Complaints Committee, including an external member, at every branch or office location — waiting until a complaint arises is itself a violation.
Clinical Establishment RegistrationEvery clinical establishment must be registered with the applicable state or central registering authority before operating — which specific law applies depends on the state it is located in.
Lifts & escalatorsA lift runs on a licence and a maintenance contract that both expire. Where the state has a lift Act you get its statutory tests and filings; everywhere you get monthly maintenance, rescue-device checks and an accident log, because the owner answers for a defect that was known and not fixed.
Trade licenceHotels, restaurants, hospitals, shops and most commercial premises need a trade licence from the local body, and it is often a prerequisite for other licences and utility connections.
Environmental Statement (Form V)If your premises runs under an SPCB consent to operate (for an STP, ETP, DG set or boiler) or a hazardous-waste authorisation, you owe the Board a yearly environmental statement — water and raw-material use, pollutants discharged, hazardous and solid waste generated, and measures taken. It is easy to miss because no renewal prompts it.
Hazardous Waste (HWM Rules 2016)Hazardous waste generated on the premises (used lubricating oil from a DG set, spent solvents, lab or cleaning chemicals and their residues or empty containers) requires SPCB authorization, manifested handover to an authorized recycler/TSDF, and an annual return.
Rainwater harvestingWhere the state binds existing buildings, a missing or non-working structure is a standing violation and can raise the water bill; elsewhere it is the approval-time condition most often left unmaintained.
RuleWhat it asks of you
Fire Safety (NOC & Systems)Buildings above a certain height/occupancy (threshold varies by state) need a Fire Safety NOC, working fire-fighting systems (extinguishers, hydrants, sprinklers), and regular fire drills — facility management is directly responsible for this, not just the builder.
Shops & Establishments RegistrationNearly every commercial or institutional premises operating in India needs Shops & Establishments registration from the state labour department or municipal corporation — this is separate from any sector-specific licence and applies regardless of business type.
Electrical safetyEvery premises has an electrical installation that needs a current inspection or self-certification. Most fires in buildings start electrically, and a lapsed inspection is the first thing an insurer or investigator asks for.
Occupancy & structureThe occupancy certificate is the document other licences ask for; in Maharashtra and Gujarat an older building also needs a current structural stability certificate.
Site labour dutiesThese are the labour duties that show up on site — a stocked first-aid box, an accident notice, and proof that the agencies supplying your housekeeping and security staff are licensed. Wages, provident fund and ESI stay with payroll.
Personal data protectionResident, visitor, guest, patient, student and staff records — and CCTV — are personal data. The core duties start on 13 May 2027; these tasks get the notice, breach plan and grievance contact in place before then.

This guide explains how the app helps you keep records. It is not legal advice; your regulator's notification is the final word.

10. Job sheets for each person

Print the section for each person and hand it over with their login. It lists only the jobs that are usually theirs; their role guide explains how to do any job in the app.

Manager

Every year

  • Food handling staff annual medical fitness certificates
  • Annual HSD tank integrity inspection (only if Diesel Storage Licence (PESO) applies)

How to do these in the app: Manager guide.

Bio-medical waste coordinator (Manager access)

Every day

  • NDPS controlled substance daily stock/dispensing/balance register

Every six months

  • BMW segregation and handling staff training

Each time it happens

  • Patient-surrendered drugs on admission — formal surrender record
  • CBWTF barcode-scan / handover record per collection visit

How to do these in the app: Manager guide.

Housekeeping / floor staff (Worker access)

Every day

  • Daily waste log by stream (weigh on collection days)
  • Daily organic waste processing log (Option A)
  • Daily C&D waste volume log by category (only if Construction & Demolition (C&D) Waste applies)
  • Daily borewell pump run log (each borewell) (only if Groundwater Extraction (CGWA) applies)

Every week

  • On-site C&D waste segregation zone photo (4-category) (only if Construction & Demolition (C&D) Waste applies)
  • Weekly groundwater abstraction log (per borewell) (each borewell) (only if Groundwater Extraction (CGWA) applies)

Every month

  • Monthly groundwater level monitoring (each borewell) (only if Groundwater Extraction (CGWA) applies)
  • Monthly STP performance log (each STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • Treated effluent reuse log (gardening/flushing) (each STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • STP sludge disposal log (each STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • Sanitary waste stream handover log (SWM 2026)
  • Special-care waste stream handover log (SWM 2026)
  • Septic tank / cesspool desludging log (each septic tank) (only if Sewage Treatment Plant (STP) Consent applies)

Each time it happens

  • DG run log entry (per operation) (each DG set) (only if Diesel Generator (DG) Air & Noise Norms applies)

How to do these in the app: Worker guide.

Compliance officer (Manager access)

Every month

  • Monthly minimum standards compliance check (staffing, patient rights, emergency care)

Every six months

  • 6-monthly certified fire system inspection (IS 2190)

Every year

  • BMW Annual Return Form IV (June 30)
  • Annual SWM return filing
  • Annual fire system service / hydro-test (IS 2190)
  • POSH annual report to District Officer (only if POSH Internal Complaints Committee applies)
  • Annual waste generation report to State Health Authority (only if Clinical Establishment Registration applies)
  • 2-year STP installation plan / approval (no on-site STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • Environmental Statement (Form V) to the SPCB (30 September) (only if Environmental Statement (Form V) applies)
  • HWM Form 4 annual return (June 30) (only if Hazardous Waste (HWM Rules 2016) applies)
  • Annual crèche facility review

Each time it happens

  • Personal data breach intimation
  • Bio-medical waste accident report (Form I)
  • End-of-life solar panels handed only to a registered recycler or the producer (only if E-Waste Management applies)

Before the licence expires

  • BMW authorisation renewal task
  • FSSAI licence renewal task (pre-expiry)
  • CGWA NOC renewal task (only if Groundwater Extraction (CGWA) applies)
  • PESO licence renewal task (only if Diesel Storage Licence (PESO) applies)
  • Fire NOC renewal task
  • Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)
  • Clinical Establishment registration renewal task (permanent registration, 5-year validity) (only if Clinical Establishment Registration applies)
  • Lift licence / registration — renewal (each lift) (only if Lifts & escalators applies)
  • Lift maintenance contract (AMC) — renewal (only if Lifts & escalators applies)
  • Lift third-party insurance — renewal (only if Lifts & escalators applies)
  • Electrical installation inspection / self-certification — renewal
  • Municipal trade / health trade licence — renewal (only if Trade licence applies)
  • Structural stability certificate — renewal
  • Contractor labour licences (50 or more contract workers) — renewal
  • Security agency licence (PSARA) — renewal
  • HWM authorisation renewal task (only if Hazardous Waste (HWM Rules 2016) applies)

Before the licence expires

  • STP CTO renewal task (each STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • SPCB DG set CTO renewal task (only if Diesel Generator (DG) Air & Noise Norms applies)

How to do these in the app: Manager guide.

Nurse / ward in-charge (Supervisor access)

Every day

  • BMW daily generation log by enabled category

Every month

  • Monthly lift maintenance visit (each lift) (only if Lifts & escalators applies)
  • Monthly first-aid box check

Every quarter

  • Quarterly lift test by a registered person (each lift) (only if Lifts & escalators applies)
  • Lift rescue device, alarm and intercom check (each lift) (only if Lifts & escalators applies)

Every six months

  • Six-monthly lift test by an authorised person (each lift) (only if Lifts & escalators applies)
  • Lift rescue mock drill (only if Lifts & escalators applies)

Every year

  • Annual lift safety certificate / inspection report (only if Lifts & escalators applies)
  • Annual earth resistance test
  • Electrical Safety Officer annual inspection and test report
  • Annual review and erasure of personal data no longer needed

Each time it happens

  • Lift accident report to the inspector (only if Lifts & escalators applies)
  • Electrical accident intimation
  • Workplace accident / dangerous occurrence notice

How to do these in the app: Supervisor guide.

Pharmacy in-charge (Supervisor access)

Each time it happens

  • Expired/recalled non-cytotoxic medicine disposal log

How to do these in the app: Supervisor guide.

Kitchen supervisor (Supervisor access)

Every month

  • FSSAI Schedule 4 monthly hygiene inspection
  • UCO handover to FSSAI-registered UCO aggregator

Every year

  • FSSAI annual fee payment + Food Safety Compliance Report (FSCR) filing

How to do these in the app: Supervisor guide.

Operations supervisor (Supervisor access)

Every week

  • No unauthorized C&D dumping declaration (only if Construction & Demolition (C&D) Waste applies)

Every month

  • Monthly single-use plastic ban audit
  • Plastic waste dispatch to CPCB-authorized recycler
  • Fire system maintenance (extinguishers, hydrants, sprinklers)
  • Monthly no-open-burning declaration
  • Monthly STP effluent quality test (each STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • No effluent to groundwater declaration (only if Sewage Treatment Plant (STP) Consent applies)
  • Monthly rainwater harvesting structure maintenance log (each rainwater pit) (only if Groundwater Extraction (CGWA) / Rainwater harvesting applies)
  • Used engine oil handover to a registered collection agent / recycler (only if Hazardous Waste (HWM Rules 2016) applies)

Every quarter

  • Quarterly fire escape signage and emergency lighting check
  • Fire drill and staff evacuation training record

Every year

  • Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set) (only if Diesel Generator (DG) Air & Noise Norms applies)
  • Annual noise level test at property boundary (only if Noise Pollution Rules applies)
  • Fuel storage area fire safety check (only if Diesel Storage Licence (PESO) applies)
  • Hepatitis B and tetanus immunisation of staff handling bio-medical waste
  • Health check-up of staff handling bio-medical waste

Each time it happens

  • E-waste handover receipt from registered producer/refurbisher/recycler (only if E-Waste Management applies)
  • Spent battery handover receipt / take-back confirmation (only if Battery Waste Management applies)
  • C&D waste dispatch to authorized processor receipt (only if Construction & Demolition (C&D) Waste applies)
  • Faecal sludge transport manifest / FSTP receipt (each septic tank) (only if Sewage Treatment Plant (STP) Consent applies)

How to do these in the app: Supervisor guide.