Browse all help

Guides

How do I…?

Signing in and the app7
Doing jobs13
Checking jobs and running the team10
Setting up and managing17
Collection, intake and gate7

By type of organisation

Airport / Aerodrome: setup and training guide

On this page

This page is the part of the onboarding kit that is specific to a Airport / Aerodrome. It lists what the app will set up for you, who in your team normally does each piece, and what you need to have ready. How to use the app is in the shared guides, which are the same for every organisation:

The lists below come from the same rule set the app uses, so they match what you will see. What actually applies to your site depends on your answers during setup: a rule marked "depends on your site" is only switched on if you have, for example, a borewell or a kitchen.

1. At a glance

WhatHow many (maximum)
Rules that apply to every Airport10
Rules that depend on what is on your site15
Good-practice rules (recommended)8
One-time setup items (photos, documents, certificates)64
Recurring jobs (daily to yearly)63
Things you log when they happen15
Licence renewals tracked21
Statutory filings4

Most sites end up with fewer than the maximum, because the setup questions switch off what does not apply.

2. Who you need on the app

Each row is a job in your organisation, not necessarily a separate person. In a small site one person often holds several rows: the manager is usually also the compliance officer. Every person signs in with their own account, so the record shows who did what.

RoleApp accessWhat they look afterNeeded?Items they own
ManagerManagerOverall compliance, authorizations, annual returnsYes54
Compliance officerManagerHWM manifests, CPCB portals, sector-specific reportsYes41
Operations supervisorSupervisorWorkshop HWM, OWS log, DG, HVACYes52
Tenant compliance liaisonSupervisorFood stall FSSAI audits, tenant plastic-bag auditsYes2
Housekeeping / floor staffWorkerDaily waste log, CO monitoring, Swachh Rail inspection tasksYes18

App access decides what a person sees. Manager: the web portal and the phone app, with setup, approvals, reports and filings. Supervisor: the phone app, with their team's jobs and approvals. Worker: the phone app, with their own jobs only.

3. Before setup: have these ready

Questions the setup will ask about your site

Setup takes about 30 to 45 minutes if you have these answers to hand. "Not sure" is fine for anything you can find out later; you can change answers afterwards.

Numbers

  • Number of lifts
  • Number of escalators / moving walks
  • Connected electrical load (kW)
  • Age of the building (years)
  • Contract workers engaged through contractors
  • Plot area (sq m)
  • Solar plant capacity (kW)
  • Number of employees / workers on site

Yes or no

  • Borewell on site?
  • Central HVAC on site?
  • Workshop or STP on site?
  • Active renovation on site?
  • Rainwater harvesting on site?
  • Employs 10 or more people (incl. contract/interns)?
  • Uses septic tank / storage tank (no onsite STP)?
  • Handles international flights?
  • Has an active expansion / greenfield project?
  • Operates ground support equipment / vehicle fleet?
  • Participates in ACI Airport Carbon Accreditation?
  • Local body requires a trade licence?
  • Security guards supplied by an agency?
  • Holds an Environmental Clearance (EIA 2006)?
  • Airport medical inspection room / first-aid post?
  • Airport operator runs its own kitchen / food outlet?
  • State law requires rainwater harvesting here (derived from state and plot area; not asked)?
  • Rooftop / ground-mounted solar plant on site?
  • Uses more than 50 litres of frying oil a day (FSSAI UCO threshold)?

Other details

  • No-STP wastewater scenario

Documents and licences to gather

Collect what you already have as PDFs or clear phone photos. Anything you do not have yet stays on your list as a gap; it does not block setup.

DocumentNeeded
☐ DGCA Wildlife Hazard Management Plan (garbage/attractant source control)Always
☐ CPCB BWG registrationAlways
☐ SPCB HWM authorizationAlways
☐ FSSAI licenseAlways
☐ Battery asset register (UPS/inverter/solar systems)Always
☐ Electrical and electronic equipment (EEE) asset registerAlways
☐ CGWA NOC or exemption certificateIf Groundwater Extraction (CGWA) applies
☐ Rainwater harvesting system installation certificate (each rainwater pit)If Groundwater Extraction (CGWA) / Rainwater harvesting applies
☐ Fire Safety NOC from State Fire ServiceAlways
☐ ETP/STP SPCB Consent to Operate (each ETP)If Effluent Treatment Plant (ETP) applies
☐ HVAC refrigerant inventoryIf Ozone-Depleting Substances (ODS) applies
☐ R-22 phase-out planIf Ozone-Depleting Substances (ODS) applies
☐ PESO petroleum storage licenseAlways
☐ HSD tank vapor recovery system installation certificateAlways
☐ SPCB Consent to OperateAlways
☐ C&D Waste Management PlanIf Construction & Demolition (C&D) Waste applies
☐ ULB approval/intimation for large C&D projectsIf Construction & Demolition (C&D) Waste applies
☐ SPCB Consent to Operate (CTO) for diesel generator (DG)Always
☐ Shops & Establishments Act registrationAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)If POSH Internal Complaints Committee applies
☐ STP Consent to Operate from SPCB (each STP)If Effluent Treatment Plant (ETP) applies
☐ AQCS-approved incineration / disposal contractor agreementIf International Catering Waste (AQCS) applies
☐ EIA Environment Clearance conditions documentIf Environmental Clearance (EIA) applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)Always
☐ Lift licence / registration (each lift)If Lifts & escalators applies
☐ Lift maintenance contract (AMC)If Lifts & escalators applies
☐ Lift third-party insuranceIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationAlways
☐ Electrical Safety Officer appointmentAlways
☐ Fire-safe wiring and supply isolation certificateAlways
☐ Municipal trade / health trade licenceIf Trade licence applies
☐ Occupancy / completion certificateAlways
☐ Structural stability certificateAlways
☐ Contractor labour licences (50 or more contract workers)Always
☐ Security agency licence (PSARA)Always
☐ Privacy notice for residents / visitors / customers / staffAlways
☐ Personal data breach response planAlways
☐ CBWTF contract + SPCB auth (if sharps/BMW generated)If BMW Rules 2016 (medical room / first aid) applies
☐ DGCA aerodrome licenceAlways
☐ BCAS aerodrome security programme approvalAlways
☐ Electrical Inspector approval of the rooftop solar plantAlways
☐ Self-certification of the rooftop solar plantAlways
☐ Net-metering / grid connection agreement with the discomAlways
☐ Crèche facility for employees' children (50 or more employees)Always
☐ Pest-control operator's licence (Insecticides Rules 1971)Always

4. Setup evidence: your first-weeks checklist

Setup evidence is the one-time proof of what is on your site: a photo of each bin, the STP nameplate, a copy of each licence. After setup each item appears as a job under Setup Evidence. Photo items for equipment start with a scan of that item's QR sticker, so stick the stickers on first (see Setup evidence and QR stickers).

Compliance officer

ItemEvidenceNeeded
☐ DGCA Wildlife Hazard Management Plan (garbage/attractant source control)DocumentAlways
☐ CPCB BWG registrationCertificateAlways
☐ SPCB HWM authorizationCertificateAlways
☐ FSSAI licenseCertificateAlways
☐ CGWA NOC or exemption certificateCertificateIf Groundwater Extraction (CGWA) applies
☐ Fire Safety NOC from State Fire ServiceCertificateAlways
☐ ETP/STP SPCB Consent to Operate (each ETP)CertificateIf Effluent Treatment Plant (ETP) applies
☐ R-22 phase-out planDocumentIf Ozone-Depleting Substances (ODS) applies
☐ PESO petroleum storage licenseCertificateAlways
☐ HSD tank vapor recovery system installation certificateCertificateAlways
☐ SPCB Consent to OperateCertificateAlways
☐ ULB approval/intimation for large C&D projectsDocumentIf Construction & Demolition (C&D) Waste applies
☐ SPCB Consent to Operate (CTO) for diesel generator (DG)CertificateAlways
☐ Shops & Establishments Act registrationCertificateAlways
☐ POSH Internal Complaints Committee constitution (incl. external member)DocumentIf POSH Internal Complaints Committee applies
☐ STP Consent to Operate from SPCB (each STP)CertificateIf Effluent Treatment Plant (ETP) applies
☐ AQCS-approved incineration / disposal contractor agreementCertificateIf International Catering Waste (AQCS) applies
☐ EIA Environment Clearance conditions documentDocumentIf Environmental Clearance (EIA) applies
☐ EBWGR certificates (dry, sanitary and special-care waste; wet waste if not processed on site)CertificateAlways

Manager

ItemEvidenceNeeded
☐ Bin overview photo (position, label & lid) — per bin (each bin)PhotoAlways
☐ DG acoustic enclosure installation photo (each DG set)PhotoAlways
☐ Battery asset register (UPS/inverter/solar systems)DocumentAlways
☐ Electrical and electronic equipment (EEE) asset registerDocumentAlways
☐ Rainwater harvesting system installation certificate (each rainwater pit)DocumentIf Groundwater Extraction (CGWA) / Rainwater harvesting applies
☐ HVAC refrigerant inventoryDocumentIf Ozone-Depleting Substances (ODS) applies
☐ C&D Waste Management PlanDocumentIf Construction & Demolition (C&D) Waste applies
☐ Composting unit full overview (each compost unit)PhotoAlways
☐ Diesel generator (DG) set — full installation overview (each DG set)PhotoAlways
☐ STP full installation overview (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ Consent-to-Operate document displayed near STP (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ Dedicated international catering waste (ICW) bins and holding areaPhotoIf International Catering Waste (AQCS) applies
☐ Lift / escalator nameplate photo (each lift)PhotoIf Lifts & escalators applies
☐ Lift licence / registration (each lift)CertificateIf Lifts & escalators applies
☐ Lift maintenance contract (AMC)CertificateIf Lifts & escalators applies
☐ Lift third-party insuranceCertificateIf Lifts & escalators applies
☐ Electrical installation inspection / self-certificationCertificateAlways
☐ Electrical Safety Officer appointmentDocumentAlways
☐ Fire-safe wiring and supply isolation certificateDocumentAlways
☐ Municipal trade / health trade licenceCertificateIf Trade licence applies
☐ Occupancy / completion certificateCertificateAlways
☐ Structural stability certificateCertificateAlways
☐ Contractor labour licences (50 or more contract workers)CertificateAlways
☐ Security agency licence (PSARA)CertificateAlways
☐ Privacy notice for residents / visitors / customers / staffDocumentAlways
☐ Named contact for personal-data grievancesDeclarationAlways
☐ Personal data breach response planDocumentAlways
☐ BMW assessment declaration — medical room / first-aidDeclarationIf BMW Rules 2016 (medical room / first aid) applies
☐ CBWTF contract + SPCB auth (if sharps/BMW generated)DocumentIf BMW Rules 2016 (medical room / first aid) applies
☐ DGCA aerodrome licenceCertificateAlways
☐ BCAS aerodrome security programme approvalCertificateAlways
☐ Electrical Inspector approval of the rooftop solar plantDocumentAlways
☐ Self-certification of the rooftop solar plantDocumentAlways
☐ Net-metering / grid connection agreement with the discomDocumentAlways
☐ Crèche facility for employees' children (50 or more employees)DocumentAlways
☐ Pest-control operator's licence (Insecticides Rules 1971)CertificateAlways

Operations supervisor

ItemEvidenceNeeded
☐ Four-stream segregation signage and bin infrastructure photoPhotoAlways
☐ Composting unit capacity label (each compost unit)PhotoAlways
☐ Compost output storage area (each compost unit)PhotoAlways
☐ Diesel generator (DG) capacity nameplate (each DG set)PhotoAlways
☐ STP capacity nameplate or equipment label (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ STP inlet connection from building drainage (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ STP outlet pipe destination connection (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ STP sludge disposal / drying area (each STP)PhotoIf Effluent Treatment Plant (ETP) applies
☐ Electrical danger notices and shock-treatment chartPhotoAlways

5. Your recurring jobs

These are created automatically once setup is done and come back on their own schedule. Each shows on the phone of the person it is assigned to. The "Usually done by" column is the default; the manager can reassign any job (see Manager guide).

Every day

JobUsually done byEvidenceNeeded
Daily waste weighment logHousekeeping / floor staffReadingsAlways
Food and garden waste composting / processing logHousekeeping / floor staffReadingsAlways
Daily C&D waste volume log by categoryHousekeeping / floor staffReadingsIf Construction & Demolition (C&D) Waste applies
Daily borewell pump run log (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies
Daily garden/leaf waste composting or disposal logHousekeeping / floor staffReadingsAlways

Every week

JobUsually done byEvidenceNeeded
On-site C&D waste segregation zone photo (4-category)Housekeeping / floor staffPhotoIf Construction & Demolition (C&D) Waste applies
No unauthorized C&D dumping declarationOperations supervisorDeclarationIf Construction & Demolition (C&D) Waste applies
Weekly groundwater abstraction log (per borewell) (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies

Every month

JobUsually done byEvidenceNeeded
Workshop oil-water separator cleaning and skimmed-oil disposal logHousekeeping / floor staffDocumentAlways
Basement parking ventilation and CO monitoring log (good practice)Compliance officerReadingsAlways
Monthly garbage/attractant-source and wildlife activity inspection (Aircraft Rules 1937, Rule 91)Operations supervisorChecklistAlways
Dry waste dispatch to authorized recyclerHousekeeping / floor staffDocumentAlways
HWM storage inspection (≤90 days, no mixing)Operations supervisorPhotoAlways
Monthly Schedule 4 hygiene inspectionOperations supervisorChecklistAlways
Pest control treatment recordOperations supervisorDocumentAlways
UCO handover to FSSAI-registered aggregatorHousekeeping / floor staffDocumentAlways
Monthly single-use plastic ban audit (terminal concessions)Operations supervisorChecklistAlways
Dry plastic waste to authorized recyclerOperations supervisorDocumentAlways
Monthly groundwater level monitoring (each borewell)Housekeeping / floor staffReadingsIf Groundwater Extraction (CGWA) applies
Fire system maintenance (extinguishers, hydrants, sprinklers)Operations supervisorDocumentAlways
Cooling tower blowdown water quality and disposal logHousekeeping / floor staffDocumentIf Effluent Treatment Plant (ETP) applies
Monthly ETP performance log (each ETP)Housekeeping / floor staffReadingsIf Effluent Treatment Plant (ETP) applies
Monthly ETP effluent quality test (each STP)Operations supervisorDocumentIf Effluent Treatment Plant (ETP) applies
ETP sludge disposal log/receipt (each ETP)Operations supervisorDocumentIf Effluent Treatment Plant (ETP) applies
No effluent to groundwater declaration (each STP)Operations supervisorDeclarationIf Effluent Treatment Plant (ETP) applies
Kitchen grease trap monthly cleaning (each grease trap)Operations supervisorDocumentAlways
Monthly tenant carry-bag compliance audit across all retail unitsTenant compliance liaisonChecklistAlways
Sanitary waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Special-care waste stream handover log (SWM 2026)Housekeeping / floor staffDocumentAlways
Monthly no-open-burning declarationOperations supervisorDeclarationAlways
Monthly rainwater harvesting structure maintenance log (each rainwater pit)Operations supervisorDocumentIf Groundwater Extraction (CGWA) / Rainwater harvesting applies
Septic tank / cesspool desludging log (each septic tank)Housekeeping / floor staffDocumentIf Sewage Treatment Plant (STP) Consent applies
Monthly wildlife/bird strike record and DGCA reporting logOperations supervisorReadingsAlways
Monthly lift maintenance visit (each lift)Operations supervisorChecklistIf Lifts & escalators applies
Monthly first-aid box checkOperations supervisorChecklistAlways
Used engine oil handover to a registered collection agent / recyclerOperations supervisorReadingsAlways

Every quarter

JobUsually done byEvidenceNeeded
Quarterly fire escape signage and emergency lighting checkOperations supervisorPhotoAlways
Fire drill and staff evacuation training recordOperations supervisorDocumentAlways
Quarterly data centre / UPS room / DG room fire safety checkOperations supervisorChecklistAlways
Airfield Environment Management Committee (AEMC) meeting minutesCompliance officerDocumentAlways
Quarterly lift test by a registered person (each lift)Operations supervisorDocumentIf Lifts & escalators applies
Lift rescue device, alarm and intercom check (each lift)Operations supervisorChecklistIf Lifts & escalators applies
Airport ambient noise monitoring reportOperations supervisorDocumentAlways

Every six months

JobUsually done byEvidenceNeeded
6-monthly certified fire system inspection (IS 2190)Compliance officerDocumentAlways
6-monthly EC compliance report (if EC granted)Compliance officerDocumentIf Environmental Clearance (EIA) applies
Six-monthly lift test by an authorised person (each lift)Operations supervisorDocumentIf Lifts & escalators applies
Lift rescue mock drillOperations supervisorDocumentIf Lifts & escalators applies

Every year

JobUsually done byEvidenceNeeded
ACI Airport Carbon Accreditation certificate (voluntary)Compliance officerDocumentIf Airport Sector Guidance (ACI) applies
Kitchen staff annual health certificateManagerDocumentAlways
Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set)Operations supervisorDocumentAlways
Annual noise level test at property boundaryOperations supervisorDocumentAlways
Annual audit that all food court tenants hold valid FSSAI licenseTenant compliance liaisonDocumentAlways
Annual HSD tank integrity inspectionManagerDocumentAlways
Annual fire system service / hydro-test (IS 2190)Compliance officerDocumentAlways
Annual refrigerant top-up review and leak auditCompliance officerDocumentIf Ozone-Depleting Substances (ODS) applies
POSH annual report to District OfficerCompliance officerDocumentIf POSH Internal Complaints Committee applies
2-year STP installation plan / approval (no on-site STP)Compliance officerDocumentIf Sewage Treatment Plant (STP) Consent applies
Annual 10 km attractant-source survey (garbage dumps, abattoirs, meat/fish shops)Compliance officerDocumentAlways
Annual lift safety certificate / inspection reportOperations supervisorDocumentIf Lifts & escalators applies
Annual earth resistance testOperations supervisorDocumentAlways
Electrical Safety Officer annual inspection and test reportOperations supervisorDocumentAlways
Annual review and erasure of personal data no longer neededOperations supervisorChecklistAlways
Annual crèche facility reviewManagerChecklistAlways

6. Things you log when they happen

These have no fixed date. Log them in the app on the day they happen, so the record is made at the time and not rebuilt later.

WhatWhenUsually logged byNeeded
HWM Form 10 dispatch manifest (per hazardous dispatch)Each time it happensOperations supervisorAlways
Spent battery handover receipt / take-back confirmationEach time it happensOperations supervisorAlways
E-waste handover receipt from registered producer/refurbisher/recyclerEach time it happensOperations supervisorAlways
HVAC/chiller service logEach time it happensHousekeeping / floor staffIf Ozone-Depleting Substances (ODS) applies
ELT dispatch receipt from authorized retreader/pyrolysis facilityEach time it happensHousekeeping / floor staffIf Waste Tyre EPR applies
C&D waste dispatch to authorized processor receiptEach time it happensOperations supervisorIf Construction & Demolition (C&D) Waste applies
Refrigerant recovery cert at decommissionEach time it happensManagerIf Ozone-Depleting Substances (ODS) applies
Faecal sludge transport manifest / FSTP receipt (each septic tank)Each time it happensOperations supervisorIf Sewage Treatment Plant (STP) Consent applies
International catering waste disposal manifest — per offload consignmentEach time it happensOperations supervisorIf International Catering Waste (AQCS) applies
Lift accident report to the inspectorEach time it happensOperations supervisorIf Lifts & escalators applies
Electrical accident intimationEach time it happensOperations supervisorAlways
Workplace accident / dangerous occurrence noticeEach time it happensOperations supervisorAlways
Personal data breach intimationEach time it happensManagerAlways
Expired medicine disposal from medical roomEach time it happensOperations supervisorIf BMW Rules 2016 (medical room / first aid) applies
End-of-life solar panels handed only to a registered recycler or the producerEach time it happensManagerAlways

7. Licence renewals

Enter the expiry date of each licence when you upload it. The app then creates the renewal job ahead of the expiry, so nobody has to remember the date.

RenewalOwnerNeeded
FSSAI licence renewal task (pre-expiry)Compliance officerAlways
CGWA NOC renewal taskCompliance officerIf Groundwater Extraction (CGWA) applies
Fire NOC renewal taskCompliance officerAlways
ETP CTO renewal taskCompliance officerIf Effluent Treatment Plant (ETP) applies
HWM authorisation renewal taskCompliance officerAlways
PESO licence renewal taskCompliance officerAlways
SPCB CTO renewal taskCompliance officerAlways
SPCB DG set CTO renewal taskCompliance officerAlways
Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)Compliance officerAlways
STP Consent-to-Operate (CTO) renewalCompliance officerIf Effluent Treatment Plant (ETP) applies
Lift licence / registration — renewalManagerIf Lifts & escalators applies
Lift maintenance contract (AMC) — renewalManagerIf Lifts & escalators applies
Lift third-party insurance — renewalManagerIf Lifts & escalators applies
Electrical installation inspection / self-certification — renewalManagerAlways
Municipal trade / health trade licence — renewalManagerIf Trade licence applies
Structural stability certificate — renewalManagerAlways
Contractor labour licences (50 or more contract workers) — renewalManagerAlways
Security agency licence (PSARA) — renewalManagerAlways
DGCA aerodrome licence — renewalManagerAlways
BCAS aerodrome security programme approval — renewalManagerAlways
Pest-control operator's licence (Insecticides Rules 1971) — renewalManagerAlways

8. Your filing calendar

Filings are statutory returns you submit to a regulator. The app reminds the owner ahead of each due date and collects the figures from the jobs your team has done through the year, so the return is built from real records.

FilingDueWhereRuleNeeded
SWM ANNUAL RETURN30 June every year–Solid Waste Management (SWM) 2026Always
HWM ANNUAL RETURN30 June every year–HWM Rules 2016 — Airside & MaintenanceAlways
FSSAI Annual Fee + FSCR Filing31 March every yearFoSCoSFood Safety (FSSAI)Always
Environmental Statement (Form V)30 September every yearState SPCB portalEnvironmental Statement (Form V)Always

9. The rules behind all this

Applies to every site of this type

RuleWhat it asks of you
Solid Waste Management (SWM) 2026Requires segregating waste into 4 streams (wet/dry/sanitary/special-care), registering as a Bulk Waste Generator, and either composting wet waste on-site or obtaining an EBWGR certificate from the local body.
HWM Rules 2016 — Airside & MaintenanceAirside maintenance, ground-support-equipment servicing, the fuel farm and de-icing operations generate spent solvent, waste oil, contaminated rags and tank sludge. That is hazardous waste: it needs SPCB authorisation, manifested handover to an authorised recycler or TSDF, and an annual return — it cannot go out with terminal waste.
Food Safety (FSSAI)Running a restaurant, café, or canteen needs an FSSAI licence and requires following hygiene and used-cooking-oil disposal rules.
Plastic Waste ManagementCovers segregating plastic waste, the single-use-plastic ban, and handing dry plastic over to authorised recyclers — applies regardless of org size.
Diesel Generator (DG) Air & Noise NormsRunning a diesel generator for power backup needs SPCB consent, an acoustic enclosure, and periodic stack-emission testing.
Noise Pollution RulesLimits DG-set and loudspeaker noise, including a 10pm-6am night restriction — enforced by the District Magistrate/Police, not SPCB.
Battery Waste ManagementUPS/inverter batteries and other battery waste must be segregated and handed to an authorised collector, not thrown out with general waste.
E-Waste ManagementE-waste (UPS batteries, old electronics, lighting) must go only to a registered recycler — no separate CPCB registration is needed as a bulk consumer.
Diesel Storage Licence (PESO)Storing more than 2,500L of diesel for DG backup requires a PESO storage licence and periodic tank safety certification.
Aircraft Rules 1937, Rule 91An airport is legally responsible for keeping bird and animal attractants — open garbage, food waste, slaughter and meat-processing activity — out of a 10 km radius around the aerodrome reference point. Waste handling on and around the airfield is therefore an air-safety obligation, not just a municipal one: an uncontrolled garbage dump inside the radius is what turns into a bird strike.

Depends on what is on your site

RuleWhat it asks of you
Groundwater Extraction (CGWA)If groundwater is drawn from a borewell/tube well, CGWA requires monthly groundwater-level monitoring reported through their portal.
Effluent Treatment Plant (ETP)If this facility operates its own Effluent Treatment Plant for process or greywater effluent, it needs SPCB Consent to Operate, regular effluent-quality capture, and proper sludge disposal — separate from any domestic-sewage STP.
Ozone-Depleting Substances (ODS)Restricts servicing or topping up older AC/refrigeration equipment that relies on CFC/HCFC refrigerants.
Waste Tyre EPRIf this facility collects, stores, or processes waste tyres, it must register on the CPCB EPR Tyres portal and generate EPR certificates for processed tyre material (crumb rubber, reclaimed rubber, pyrolysis oil).
Airport Sector Guidance (ACI)Airports participating in Airport Council International programmes — Airport Carbon Accreditation or the ACI Green Airports recognition — commit to waste-management reporting beyond the statutory baseline. Voluntary, but once you are enrolled the annual report is a commitment you are audited against.
Construction & Demolition (C&D) WasteAny renovation or demolition work must segregate C&D waste per the local authority's plan; projects over 20,000 sq.m also need EPR portal registration.
POSH Internal Complaints CommitteeAny workplace with 10 or more employees must proactively constitute an Internal Complaints Committee, including an external member, at every branch or office location — waiting until a complaint arises is itself a violation.
Sewage Treatment Plant (STP) ConsentOperating an on-site STP needs SPCB Consent to Operate plus monthly performance and sludge-disposal logs.
International Catering Waste (AQCS)Waste offloaded from an international flight cannot enter the airport's ordinary wet/dry waste stream. It is a biosecurity control against exotic livestock and plant disease entering India, so it needs its own segregated chain from aircraft to incinerator, with the manifest to prove it.
Environmental Clearance (EIA)Projects near sensitive ecosystems or within 10km of a protected area need prior Environmental Clearance before construction begins.
Lifts & escalatorsA lift runs on a licence and a maintenance contract that both expire. Where the state has a lift Act you get its statutory tests and filings; everywhere you get monthly maintenance, rescue-device checks and an accident log, because the owner answers for a defect that was known and not fixed.
Trade licenceHotels, restaurants, hospitals, shops and most commercial premises need a trade licence from the local body, and it is often a prerequisite for other licences and utility connections.
BMW Rules 2016 (medical room / first aid)
Rainwater harvestingWhere the state binds existing buildings, a missing or non-working structure is a standing violation and can raise the water bill; elsewhere it is the approval-time condition most often left unmaintained.
UCO (Used Cooking Oil) Handover to Authorised RUCO Aggregator
RuleWhat it asks of you
Fire Safety (NOC & Systems)Buildings above a certain height/occupancy (threshold varies by state) need a Fire Safety NOC, working fire-fighting systems (extinguishers, hydrants, sprinklers), and regular fire drills — facility management is directly responsible for this, not just the builder.
Shops & Establishments RegistrationNearly every commercial or institutional premises operating in India needs Shops & Establishments registration from the state labour department or municipal corporation — this is separate from any sector-specific licence and applies regardless of business type.
Electrical safetyEvery premises has an electrical installation that needs a current inspection or self-certification. Most fires in buildings start electrically, and a lapsed inspection is the first thing an insurer or investigator asks for.
Occupancy & structureThe occupancy certificate is the document other licences ask for; in Maharashtra and Gujarat an older building also needs a current structural stability certificate.
Site labour dutiesThese are the labour duties that show up on site — a stocked first-aid box, an accident notice, and proof that the agencies supplying your housekeeping and security staff are licensed. Wages, provident fund and ESI stay with payroll.
Personal data protectionResident, visitor, guest, patient, student and staff records — and CCTV — are personal data. The core duties start on 13 May 2027; these tasks get the notice, breach plan and grievance contact in place before then.
Aerodrome licencesAn airport cannot operate without a current DGCA aerodrome licence and an approved security programme. They are tracked here for validity only — their operating requirements are audited by DGCA and BCAS.
Environmental Statement (Form V)If your premises runs under an SPCB consent to operate (for an STP, ETP, DG set or boiler) or a hazardous-waste authorisation, you owe the Board a yearly environmental statement — water and raw-material use, pollutants discharged, hazardous and solid waste generated, and measures taken. It is easy to miss because no renewal prompts it.

This guide explains how the app helps you keep records. It is not legal advice; your regulator's notification is the final word.

10. Job sheets for each person

Print the section for each person and hand it over with their login. It lists only the jobs that are usually theirs; their role guide explains how to do any job in the app.

Manager

Every year

  • Kitchen staff annual health certificate
  • Annual HSD tank integrity inspection
  • Environmental Statement (Form V) to the SPCB (30 September)
  • Annual crèche facility review

Each time it happens

  • Refrigerant recovery cert at decommission (only if Ozone-Depleting Substances (ODS) applies)
  • Personal data breach intimation
  • End-of-life solar panels handed only to a registered recycler or the producer

Before the licence expires

  • Lift licence / registration — renewal (each lift) (only if Lifts & escalators applies)
  • Lift maintenance contract (AMC) — renewal (only if Lifts & escalators applies)
  • Lift third-party insurance — renewal (only if Lifts & escalators applies)
  • Electrical installation inspection / self-certification — renewal
  • Municipal trade / health trade licence — renewal (only if Trade licence applies)
  • Structural stability certificate — renewal
  • Contractor labour licences (50 or more contract workers) — renewal
  • Security agency licence (PSARA) — renewal
  • DGCA aerodrome licence — renewal
  • BCAS aerodrome security programme approval — renewal
  • Pest-control operator's licence (Insecticides Rules 1971) — renewal

How to do these in the app: Manager guide.

Compliance officer (Manager access)

Every month

  • Basement parking ventilation and CO monitoring log (good practice)

Every quarter

  • Airfield Environment Management Committee (AEMC) meeting minutes

Every six months

  • 6-monthly certified fire system inspection (IS 2190)
  • 6-monthly EC compliance report (if EC granted) (only if Environmental Clearance (EIA) applies)

Every year

  • ACI Airport Carbon Accreditation certificate (voluntary) (only if Airport Sector Guidance (ACI) applies)
  • SWM Annual Return (if BWG)
  • HWM Form 4 annual return (June 30)
  • Annual fire system service / hydro-test (IS 2190)
  • Annual refrigerant top-up review and leak audit (only if Ozone-Depleting Substances (ODS) applies)
  • POSH annual report to District Officer (only if POSH Internal Complaints Committee applies)
  • 2-year STP installation plan / approval (no on-site STP) (only if Sewage Treatment Plant (STP) Consent applies)
  • Annual 10 km attractant-source survey (garbage dumps, abattoirs, meat/fish shops)

Before the licence expires

  • FSSAI licence renewal task (pre-expiry)
  • CGWA NOC renewal task (only if Groundwater Extraction (CGWA) applies)
  • Fire NOC renewal task
  • HWM authorisation renewal task
  • PESO licence renewal task
  • Shops & Establishments registration renewal task (state-specific cycle; some states issue lifetime certificates)

Before the licence expires

  • ETP CTO renewal task (each ETP) (only if Effluent Treatment Plant (ETP) applies)
  • SPCB CTO renewal task
  • SPCB DG set CTO renewal task
  • STP Consent-to-Operate (CTO) renewal (each STP) (only if Effluent Treatment Plant (ETP) applies)

How to do these in the app: Manager guide.

Operations supervisor (Supervisor access)

Every week

  • No unauthorized C&D dumping declaration (only if Construction & Demolition (C&D) Waste applies)

Every month

  • Monthly garbage/attractant-source and wildlife activity inspection (Aircraft Rules 1937, Rule 91)
  • HWM storage inspection (≤90 days, no mixing)
  • Monthly Schedule 4 hygiene inspection
  • Pest control treatment record
  • Monthly single-use plastic ban audit (terminal concessions)
  • Dry plastic waste to authorized recycler
  • Fire system maintenance (extinguishers, hydrants, sprinklers)
  • Monthly ETP effluent quality test (each STP) (only if Effluent Treatment Plant (ETP) applies)
  • ETP sludge disposal log/receipt (each ETP) (only if Effluent Treatment Plant (ETP) applies)
  • No effluent to groundwater declaration (each STP) (only if Effluent Treatment Plant (ETP) applies)
  • Kitchen grease trap monthly cleaning (each grease trap)
  • Monthly no-open-burning declaration
  • Monthly rainwater harvesting structure maintenance log (each rainwater pit) (only if Groundwater Extraction (CGWA) / Rainwater harvesting applies)
  • Monthly wildlife/bird strike record and DGCA reporting log
  • Monthly lift maintenance visit (each lift) (only if Lifts & escalators applies)
  • Monthly first-aid box check
  • Used engine oil handover to a registered collection agent / recycler

Every quarter

  • Quarterly fire escape signage and emergency lighting check
  • Fire drill and staff evacuation training record
  • Quarterly data centre / UPS room / DG room fire safety check
  • Quarterly lift test by a registered person (each lift) (only if Lifts & escalators applies)
  • Lift rescue device, alarm and intercom check (each lift) (only if Lifts & escalators applies)
  • Airport ambient noise monitoring report

Every six months

  • Six-monthly lift test by an authorised person (each lift) (only if Lifts & escalators applies)
  • Lift rescue mock drill (only if Lifts & escalators applies)

Every year

  • Annual DG stack emission test (SPM/SO₂/NOₓ) (each DG set)
  • Annual noise level test at property boundary
  • FSSAI annual fee payment + Food Safety Compliance Report (FSCR) filing
  • Annual lift safety certificate / inspection report (only if Lifts & escalators applies)
  • Annual earth resistance test
  • Electrical Safety Officer annual inspection and test report
  • Annual review and erasure of personal data no longer needed

Each time it happens

  • HWM Form 10 dispatch manifest (per hazardous dispatch)
  • Spent battery handover receipt / take-back confirmation
  • E-waste handover receipt from registered producer/refurbisher/recycler
  • C&D waste dispatch to authorized processor receipt (only if Construction & Demolition (C&D) Waste applies)
  • Faecal sludge transport manifest / FSTP receipt (each septic tank) (only if Sewage Treatment Plant (STP) Consent applies)
  • International catering waste disposal manifest — per offload consignment (only if International Catering Waste (AQCS) applies)
  • Lift accident report to the inspector (only if Lifts & escalators applies)
  • Electrical accident intimation
  • Workplace accident / dangerous occurrence notice
  • Expired medicine disposal from medical room (only if BMW Rules 2016 (medical room / first aid) applies)

How to do these in the app: Supervisor guide.

Tenant compliance liaison (Supervisor access)

Every month

  • Monthly tenant carry-bag compliance audit across all retail units

Every year

  • Annual audit that all food court tenants hold valid FSSAI license

How to do these in the app: Supervisor guide.

Housekeeping / floor staff (Worker access)

Every day

  • Daily waste weighment log
  • Food and garden waste composting / processing log
  • Daily C&D waste volume log by category (only if Construction & Demolition (C&D) Waste applies)
  • Daily borewell pump run log (each borewell) (only if Groundwater Extraction (CGWA) applies)
  • Daily garden/leaf waste composting or disposal log

Every week

  • On-site C&D waste segregation zone photo (4-category) (only if Construction & Demolition (C&D) Waste applies)
  • Weekly groundwater abstraction log (per borewell) (each borewell) (only if Groundwater Extraction (CGWA) applies)

Every month

  • Workshop oil-water separator cleaning and skimmed-oil disposal log
  • Dry waste dispatch to authorized recycler
  • UCO handover to FSSAI-registered aggregator
  • Monthly groundwater level monitoring (each borewell) (only if Groundwater Extraction (CGWA) applies)
  • Cooling tower blowdown water quality and disposal log (only if Effluent Treatment Plant (ETP) applies)
  • Monthly ETP performance log (each ETP) (only if Effluent Treatment Plant (ETP) applies)
  • Sanitary waste stream handover log (SWM 2026)
  • Special-care waste stream handover log (SWM 2026)
  • Septic tank / cesspool desludging log (each septic tank) (only if Sewage Treatment Plant (STP) Consent applies)

Each time it happens

  • HVAC/chiller service log (only if Ozone-Depleting Substances (ODS) applies)
  • ELT dispatch receipt from authorized retreader/pyrolysis facility (only if Waste Tyre EPR applies)

How to do these in the app: Worker guide.