SWM Rules 2026 guide
What the SWM Rules 2026 require of IT parks, technology parks and SEZs
Yes, the Solid Waste Management Rules, 2026 (in force from 1 April 2026) apply to IT parks, technology parks and SEZs. Every waste generator must segregate into four streams at source: wet, dry, sanitary and special care.
Rule 5(2) applies if your premises is a gated community or an institution with more than 5,000 sq.m. of area. The rule says only “area”, so confirm with your local body whether it means floor or plot area. IT parks are not named as such. They fall within “industrial units and areas” or the buildings of private companies in the listed categories. Confirm with your local body how it lists your park.
At a glance
Every generator · Rule 5(1)
Four-stream segregation, sanitary waste wrapped securely, no burning, dumping or burying, and user fees.
Rule 5(2) if above 5,000 sq.m.
Separate collection, handover of recyclables to authorised agencies and on-site processing of wet waste as far as possible, within one year of notification and in partnership with the local body.
Bulk waste generator · any one test
20,000 sq.m. of floor area, 40,000 litres of water a day, or 100 kg of solid waste a day. Then registration, EBWGR certificates and the 30 June return apply.
What is different for IT parks, technology parks and SEZs
- A park’s common areas and each tenant’s floor can sit under different managements. Decide in writing who is the generator that registers, buys EBWGR certificates and files the return.
- Check floor area first: a large park can pass the 20,000 sq.m. test on its own.
- Rule 5(2) applies to institutions and gated communities above 5,000 sq.m.; confirm how your local body reads it for a managed park.
If an IT park is a bulk waste generator
Register on the CPCB portal
Registration is with your local body through the centralised portal at swm.cpcb.gov.in (Rules 6(a) and 16).
Process wet waste, or hold an exemption
New bulk waste generators must process all their wet waste. Existing ones that cannot may take an exemption from the local body.
Buy EBWGR certificates
Certificates cover the dry, sanitary and special care waste you hand over, and wet waste you do not process on site. Only the local body issues them, in kilograms, valid three years.
Use only registered partners
Do not engage any collector, transporter, recycler or processor that lacks the registration the rules require (Rule 6(g)).
File the annual return by 30 June
Filed on the same portal every year (Rules 6(h) and 20(1)).
More detail: the three tests and worked examples, EBWGR certificates explained and the annual return step by step.
What the rules do not cover
Bio-medical, hazardous, e-waste, battery, construction and demolition and industrial waste are outside the SWM Rules, 2026 and have their own rules.
The SWM Rules are one part of what applies to IT parks, technology parks and SEZs. Fire safety, electrical safety, water and sewage consents, licences and data protection come from other rules and other authorities.
The free check for IT parks, technology parks and SEZs
EarthReheal's free check for this organisation type works through 31 rules in total: 9 waste-management rules and 22 licensing and regulatory obligations beyond waste. It takes about five minutes, you see your gaps without signing up, and it is a starting point, not legal advice.
Find out where you stand in five minutes
Run the free gap check for your organisation type. It asks the questions that decide your status, tells you what applies, what is in place and what is missing, and needs no sign-up to see your gaps. From your report you can start on the free plan, or ask for a call back.
Share this guide with your committee or team
Send it to your committee, team or neighbouring organisation.
Frequently asked questions
Does the SWM Rules 2026 apply to IT parks, technology parks and SEZs?
Yes. The Solid Waste Management Rules, 2026 (in force from 1 April 2026) apply to every waste generator, so the Rule 5(1) duties apply to IT parks, technology parks and SEZs: segregate into four streams (wet, dry, sanitary and special care), wrap sanitary waste securely, never burn or dump waste, and pay user fees. Rule 5(2) applies if your premises is a gated community or an institution with more than 5,000 sq.m. of area. The rule says only “area”, so confirm with your local body whether it means floor or plot area. IT parks are not named as such. They fall within “industrial units and areas” or the buildings of private companies in the listed categories. Confirm with your local body how it lists your park.
Is an IT park a bulk waste generator?
IT parks are not named as such. They fall within “industrial units and areas” or the buildings of private companies in the listed categories. Confirm with your local body how it lists your park. A listed organisation is a bulk waste generator if it meets any one of three tests: a floor area of 20,000 sq.m., water use of 40,000 litres a day or 100 kg of solid waste a day. If it is one, it registers on the CPCB portal, buys EBWGR certificates, uses only registered partners and files an annual return by 30 June.
In an IT park, does the park or each company register?
The rules apply to the generator. If the park’s management runs the common areas, collection and handover, it is normally the generator for that waste; a tenant that runs its own collection and handover may be treated separately. The notified text does not settle this for multi-tenant parks, so get your local body’s listing in writing and record who is responsible for what.
What is not covered by the SWM Rules 2026?
Bio-medical, hazardous, e-waste, battery, construction and demolition and industrial waste are outside these rules and have their own.
How can IT parks, technology parks and SEZs check which other rules apply?
EarthReheal’s free compliance check takes about five minutes and shows you the waste rules and the other licensing and regulatory obligations that apply to your type. You see your gaps without signing up. It is a starting point, not legal advice or a certificate of compliance.
SWM Rules 2026 for other organisation types
Related guides
Sources
This is EarthReheal's plain-language summary, reviewed October 2026, for general information. It is not legal advice. Read the notified text and confirm with your local body, State Pollution Control Board or a qualified adviser before relying on it. EarthReheal is not a government body and does not file on the CPCB portal for you.